Spacing for recessed area or closet
*Recommended/Minimum spacing
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
All dimensions show recommended and minimum spacing
allowed.
n Additional spacing should be considered for ease of
installation and servicing.
n Additional clearances might be required for wall, door, and
floor moldings.
n Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
n For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
n Companion appliance spacing should also be considered.
Custom under-counter installation:
Minimum installation clearances (dryer only):
Front Sides Rear Top
Recessed
NA
0" (0 mm) 0" (0 mm)
18"
(457 mm)
to cabinet/
shelf
Closet
1" (25 mm)
Minimum
0" (0 mm) 0" (0 mm)
18"
(457 mm)
to cabinet/
shelf
Under
Counter
NA
1" (25 mm) 0" (0 mm) 0" (0 mm)
0" (0 mm) rear spacing is allowed for straight-back venting only.
For steam models only, inlet hose must not be kinked.
Mobile Home Additional installation
requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and Safety, Title
24, HUD Part 280) or the Standard for Mobile Homes, CAN/CSA-
Z240 MH.
Mobile home installations require:
n Metal exhaust system hardware, which is available for
purchase from your dealer.
n Mobile Home Installation Hold-Down Kit.
n Special provisions must be made in mobile homes to introduce
outside air into the dryer. The opening (such as a nearby
window) should be at least twice as large as the dryer exhaust
opening.
Gas Dryer Power Hookup U.S.A.
and Canada
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
120 V, 60 Hz, AC-only, 15 A or 20 A fused electrical supply is
required. A time-delay fuse or circuit breaker is recommended. It
is also recommended that a separate circuit serving only this dryer
be provided. Do not use an extension cord.