Cavity Insert Instructions
The following instructions are intended for
qualified service personnel ONLY, and should only
be done when necessary.
170°F
(77°C)
110°F
(43°C)
140°F (60°C)
In order to replace the thermostat or heating element,
remove the cavity insert crossbar by following the
instructions below:
Turn off the power to the water heater.
!
DANGER: To reduce the risk of electric shock,
disconnect all branch circuits before opening the access
panel(s). The water heater may be connected to more
than one branch circuit.
Remove the jacket access panel(s) and insulation.
Rotate the crossbar up and down until it breaks away
from the remainder of the cavity insert.
(See illustration to the left)
Discard the crossbar. It cannot and need not be
replaced.
Replace the thermostat and/or element as necessary.
Replace the insulation and jacket access panel(s)
before turning on the power to the water heater.
NOTICE: The cavity insert crossbar is necessary for
the manufacturing process only. The removal of the
crossbar will not interfere with the operation of the
water heater.