14
Inputs. . .
Encoder Toggle Function
The Input Encoder can be programmed to toggle any one of the input
functions with a single push (ie., without having to enter the Config
Menu screen). This can be very useful when, for example, experimenting with
microphone phasing.
To select a function for the Input Encoder toggle feature:
1 Enter the Config Menu screen
2 Scroll to the function required for the toggle feature
3 Press-and-hold the Input Encoder until the confirmation
message appears in the input display
The selected function will now toggle on/off each time the Input
Encoder is clicked*. If ‘Type’ (default) is selected, clicking the Input
Encoder will step through the available inputs.
*Selecting a function that is not available for the current input type will have no
effect, but the function will be stored and become active when an appropriate
input type is selected.
Line Inputs
Although some analogue input channels can be assigned to the Mic
and Instrument connectors, the remaining Line inputs are always
available on the DB25 connector(s) on the rear panel.
Operating Level Selection
(Red 16Line only – also see: ‘Input/Output Line Level Setup’ on page 26.)
The operating level for each Line input can be switched between +18
dBu and +24 dBu to correctly match additional studio equipment.
To set the level:
1 Press and hold the Input button until the Level Selection menu
appears on the Input Display
2 Scroll to the required channel number for individual selection
or to All for global selection
3 Click the Input Encoder to toggle between +18 dBu and +24 dBu
4 Press the Input button again to exit
Input and output operating level selection can be linked or unlinked. Refer to:
Global Settings – I/O Level on page 23 for additional information.
+48V
Phase
HPF
Air
Link
Mic
Type
OffOn
On Off
On
On
Off
Off
+24dBu +18dBu
Level
On Off
Input Encoder Toggle Confirmation
Loading ...
Loading ...
Loading ...