Renogy RNG-KIT-STARTER200D-RVR20 200 Watt 12 Volt Monocrystalline Solar Panel Starter 20A Rover MPPT Charge Controller/Mounting Z Brackets/Tray Cable/Adaptor Kit for RV, Boats, Trailer, Camper, Marine,Off-Grid System, 200W

User Manual - Page 64

For RNG-KIT-STARTER200D-RVR20.

PDF File Manual, 75 pages, Read Online | Download pdf file

RNG-KIT-STARTER200D-RVR20 photo
Loading ...
Loading ...
Loading ...
64
Please note the following about PWM controllers running in 24V configuration:
24V panels or 12V panels configured in series to make 24V should be used with 24V
battery system only
It is not recommended that you charge a 12V battery system with a 24V solar array. Doing
so will result in a performance loss of 50%.
The solar array should not max out the rated power of the controller. Failure to obey this
rule may result in the controller overheating or catching fire.
7.2 Overall system connections
Please refer to Figure 7.1 for the overall wiring diagram for a 24V system.
Figure 7.1 Completed 24V off-grid system
As you can see from Figure 7.1, the batteries are configured in 24V by placing two identical 12V
batteries in series. Likewise, the solar array is configured in 24V by placing two identical 12V
panels (e.g. RNG-100D) in series.
The connections for a 24V off-grid system are very similar to those of a 12V connection. The
process should be followed in the same way as outlined in
Sections 6.1 to 6.4. The only
difference is that the fuse selection changes, since a series connection increases the system Voc
to ~45v. Therefore a fuse with a voltage rating of 50v or higher is recommended, since Maxi and
ATO blade fuses have a maximum voltage rating of 32v.
With this being said, the same steps for a 12V system should be followed. Please read Sections
6.1 to 6.4
.
Loading ...
Loading ...
Loading ...