08
Turn on the power and wait for the pump to prime, which may take up to ve (5) minutes. Priming
time will depend on the veical length of the suction lift and the horizontal length of thesuction pipe.
If the pump does not prime within ve minutes, stop the motor and determine the cause. Make sure all
suction and discharge valves are open when the pump is running.See Troubleshooting Guide.
PRIMING
Fill strainer housing with water to suction pipe level. If water leakage occurs anywhere on the pump
or lter, DO NOT sta the pump. If no leakage occurs, stand at least 10 feet from the pump and/or
lter and proceed with staing the pump.
STORAGE
In order to keep the pump from the freeze in winter, please drain the pump properly:
• Keep the water level below the inlet of the pool.
• Pull out the drain plug from the pump strainer body and
remove the strainer lid.
• Disconnect pump from mounting pad, wiring system, and
piping system.
• Once water is drained o from the pump, reassemble the
strainer lid and drain plugs.
• Place pump in a shady and d area.
Voltage from the power must be in the range from 90% to 110% of the motor nameplate rated
voltage. Otherwise, the motor may overheat and result in overload tripping and reduced
component life.
Install, ground, bond, and wire motor in accordance with local or NEC requirements.
The motor should be grounded permanently by connecting the ground terminal to the electrical seice
ground.
Bond motor to pool structure. Bonding will connect all metal pas within and around the pool with
a continuous wire.
Bonding reduces the risk of current passing between bonded metal objects, which could potentially
cause electrical shock if grounded or shoed.
If any problem is found on the pump, see the Troubleshooting Guide to determine the cause and
contact the distributor to get spare pas for replacement. See Pas Guide.
SERVICING
Check the status of the pump regularly. Clean the strainer immediately if it is full of debris. Make
sure the environment is ventilated enough for the motor to cool itself.
Warning: Stop the pump and release all pressure from the circulation system before seicing.