GENERAL INSTALLATION INSTRUCTIONS
Ensure that suitable fixing screws or bolts are used to secure the units to the wall, in accordance with
AS5601 section 5. Wooden plugs shall not be used.
The top bracket has a keyhole slot so that the appliance can be positioned by hanging it on one screw,
then the other screws can be secured.
SERVICE CONNECTION POINTS
See Table 1 for individual appliance connection / fitting dimensions. Note that these dimensions are
NOT an indication of the pipe sizes required.
An Approved full flow isolation valve and disconnection union MUST be fitted to the cold water inlet.
A non return valve is not required unless required by local regulations.
Isolation Valves must not be fitted directly to the appliance.
If may be necessary to fit a temperature limiting device for delivery to areas used primarily for the
purposes of personal hygiene. Refer to the ‘Water Heater and Controllers Installation Configurations
Section of this document.
Purge gas and cold water supply lines to remove air and swarf before final connection of the
appliance. Swarf in either the gas or water supplies may cause damage.
Table 1.
If the appliance is to deliver water primarily for the purposes of personal hygiene in an
early childhood centre, primary or secondary school, nursing home or a similar facility
for the care of young, aged, sick or disabled persons as defined in AS/NZ3500.4 a
Temperature Limiting Device (TLD), such as a Tempering Valve may be required even
if the appliance is set to 50º C or less.
For these types of applications contact Rinnai.
Model:
Gas
Consumption
MJ/h
Water Supply kPa
Weight
kg
Fittings
Min. Max. Hot Cold Gas Condensate
REU-VR3237WG 250 180 1000 29 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VRM3237WC 250 180 1000 29 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VR2626WG 199 200 1000 16 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VRM2630WD 199 190 1000 17 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VRM2632WC 199 140 1000 21 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VR2632FFUG 195 140 1000 21 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VRM2632FFUC 195 140 1000 21 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-KM3237WD 211 250 1000 32 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) R ½ (15mm)
REU-KM2635WD 172 250 1000 29 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) R ½ (15mm)
REU-VR2426WB 188 200 1000 15 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VR2024WG 160 160 1000 15 R ¾ (20mm) R ¾ (20mm) R ¾ (20mm) -
REU-VR1620WG 125 120 1000 15 R ½ (15mm) R ½ (15mm) R ¾ (20mm) -
REU-VR1620WB 125 120 1000 15 R ½ (15mm) R ½ (15mm) R ¾ (20mm) -