201119 - 3650W PORTABLE GENERATOR
OPERATION
18
The generator system ground connects lower frame cross-
member below the alternator. The system ground is connected
to the AC neutral wire.
* See your Specifications section for specified type of grounding.
OPERATION
CO Shield
®
- Carbon Monoxide (CO) Detection
and Auto-shutoff System
CO Shield
®
technology monitors the accumulation of carbon
monoxide (CO), a poisonous gas produced by engine exhaust when
the generator is running. If CO Shield
®
detects unsafe elevated
levels of CO gas, it automatically shuts off the engine.
CO SHIELD IS NOT A SUBSTITUTE FOR AN INDOOR CARBON
MONOXIDE ALARM OR FOR INDOOR OPERATION.
DO NOT allow engine exhaust fumes to enter a confined area
through windows, doors, vents or other openings.
Generators must ALWAYS be used outdoors, far away from
occupied buildings with engine exhaust pointed away from people
and buildings.
If misused and operated in an unapproved and unsafe location
that results in the accumulation of poisonous CO gas inside
an enclosed or partially enclosed space, for example a house,
garage or a garage with the door partially open, CO Shield
®
will
automatically shut off the generator and then will illuminate a
blinking red LED light. Read the action label for next steps.
3473-L-SF-A
AUTOMATIC SHUTOFF – YOU MUST:
APAGADO AUTOMÁTICOUSTED DEBE:
ARRÊT AUTOMATIQUE– VOUS DEVEZ :
Move generator to an open, outdoor area. Point exhaust away.
Don’t run generators in enclosed areas (e.g. not in house or garage).
Mover el generador a un área abierta a la intemperie. Apunte el escape alejado.
No corra los generadores en áreas cerradas (ej. no en una casa o garaje).
Déplacer le générateur vers un espace
extérieur en plein air. Garder l’échappement
loin. Ne pas faire fonctionner les générateurs
dans un espace clos (ex., pas dans une
maison ou un garage).
ACTION LABEL
ETIQUETA DE ACCIÓN
ÉTIQUETTE D'ACTION
Move to fresh air and get
medical help if sick, dizzy or
weak.
Mueva al aire fresco y obtenga
asistencia medica si está
enfermo, mareado, o débil.
Aller à l'air frais et obtenir
de l'aide médicale si
malade, étourdi ou faible.
EXHAUST
EL ESCAPE
L’ECHAPPEMENT
POINT AWAY
DIRIJA ALEJADO
DIRIGER LOIN
PROCESS
ColorsAPN 3 473-L-SF
Rev A
Size ~240 x 79 mm
Artwork Notes
2mm safe margin;
to be pri nted on white s ubstrate
Revision Changes
--
This art work belongs to Cham pion Power Equipment. T he contents are con dential and privil eged and shall not be disc losed to or used by or for
outside pa rties withou t the explicit consen t of Champion Power Eq uipment.
K
485 152 109
In the event of an engine shut off, when you approach the
generator to investigate, a blinking red LED light in the CO Shield
®
area provides notification that the generator shut off due to an
accumulating CO hazard. The red LED light will blink for at least
five (5) minutes after an engine shut off event.
AUTOMATIC SHUTOFF
SEE ACTION LABEL
ARRÊT AUTOMATIQUE
VOIR L'ÉTIQUETTE D'ACTION
AUTOMATIC SHUTOFF
SEE ACTION LABEL
ARRÊT AUTOMATIQUE
VOIR L'ÉTIQUETTE D'ACTION
SERVICE
EFFECTUER
LENTRETIEN
SERVICE
EFFECTUER
LENTRETIEN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
ARRÊT AUTOMATIQUE
VOIR L'ÉTIQUETTE D'ACTION
AUTOMATIC SHUTOFF
SEE ACTION LABEL
ARRÊT AUTOMATIQUE
VOIR L'ÉTIQUETTE D'ACTION
SERVICE
EFFECTUER
LENTRETIEN
SERVICE
EFFECTUER
LENTRETIEN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
SERVICE
REALICE UN SERVICIO
SERVICE
REALICE UN SERVICIO
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOTICO
VEA ETIQUETA DE ACCIÓN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOTICO
VEA ETIQUETA DE ACCIÓN
SERVICE
REALICE UN SERVICIO
SERVICE
REALICE UN SERVICIO
Move the generator far away to an open, outdoor area and point
the exhaust away from people and buildings. Once relocated
to a safe area, the generator can be restarted, and the proper
electrical connections made. Introduce fresh air and ventilate the
location where the generator shut off.
When restarting, the red and yellow LED will blink ten (10) times
simultaneously to indicate the LED is working.
NOTICE
This blinking LED light does not indicate CO Shield
®
is working,
as CO Shield
®
is working at all times when the generator
is running. Also, the LED light will not blink (10) times if the
generator was restarted within 1 minute after it was manually
shut off. This does not occur if generator shut off from a high
CO event.
If CO Shield
®
system experiences a fault and no longer provides
protection, the generator is shutoff automatically and the yellow
LED light will blink for at least five (5) minutes to notify you of the
fault.
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOTICO
VEA ETIQUETA DE ACCIÓN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOTICO
VEA ETIQUETA DE ACCIÓN
SERVICE
REALICE UN SERVICIO
SERVICE
REALICE UN SERVICIO
Call our Technical Support Team at 1-877-338-0999 for repair.
The generator can be restarted, but will continue to shutoff.
NOTICE
CO Shield
®
will detect the accumulation of carbon monoxide
(CO) from other fuel burning sources such as engine powered
equipment, or propane heaters used in the area of operation. If
another generator is used and the exhaust stream is pointed at
a CO Shield
®
equipped generator, the CO Shield
®
may initiate
a shutoff due to rising carbon monoxide (CO) levels. This is not
a fault. Poisonous carbon monoxide (CO) has been detected.
You must take action to move and direct the generator exhaust
stream to better disperse carbon monoxide (CO) far away from
people or buildings.
Loading ...
Loading ...
Loading ...