4
ENGLISH
ELECTRICAL SPECIFICATIONS
FREQUENCY (AUTO-RANGING)
9.999Hz 0.001Hz
±(1.0% + 5 digits)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
500.00kHz 100Hz
Sensitivity:
>
8V RMS
Maximum Input: 600V DC or 600V AC RMS
DUTY CYCLE
1% to 99.9%
0.1% ±(1.2% + 2 digits)
Pulse width: 0.1 – 100ms
Frequency width: 5Hz to 10kHz
Sensitivity: >8V RMS
Maximum Input: 600V DC or 600V AC RMS
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
• Diode Test: Max. 1.5mA, open circuit voltage ~3.0V DC
• Continuity Check: Audible signal <50Ω, test current <0.35mA
• Sampling Frequency: 3 samples per second
• Low Impedence (Low Z): Input impedence >3kΩ
Max input 600V RMS
• Auto Power off: After ~30 minutes of inactivity
• Overload:
"OL" indicated on display, overload protection
1000V in Voltage setting, 600V RMS in all other settings
• Polarity: "-" on display indicates negative polarity
• Display: 3-5/6 digit, 6000 Count LCD
WARNINGS
To ensure safe operation and service of the meter, follow these
instructions. Failure to observe these warnings can result in
severe injury or death.
• Before each use verify meter operation by measuring a known
voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Use only with CAT IV rated test leads.