Electrical Shock Hazard
E[ectrka[ ground [s required on this app!iance,
Do not connect to the electrical supply until
appliance is permanently grounded,
Disconnect power to the junction box before
making the eJectrkaJ connection,
This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.
Do not use a gas supply line for grounding the
appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock,
In cold weather shipping and storage
conditions, make sure that oven is in final location at
least three (3) hours before switching on power.
Switching on power while oven is still cold may damage
the oven controls.
3. Adjusting Oven Height
Oven height can be adjusted with 2" (5 cm) wide wood
shims when needed to fit into an existing cabinet cutout
opening, when cutout height exceeds 28!/8" (71.4 cm) for
tile single wall oven or 491/2`' (125.7 cm) for the double
wall oven (see Figure 1 or 2). Place shims of appropriate
height beneath the oven side rails.
4. Electrical connection
It is the responsibility and obligation of the consumer to
contact a qualified installer to assure that the electrical
installation is adequate and is in conformance with the
National Electrical Code ANS!/NFPA No. 70qatest
edition, or with CSA Standard C22.1, Canadian
Electrical Code, Part 1, and local codes and ordinances.
Electrical ground is required on this appliance.
These appliances are equipped with a copper conductor
flexible cable. If connection is made to aluminum house
wiring, use only special connectors which are approved
forjoining copper and aluminum wires in accordance
with National Electrical Code and local codes and
ordinances.
These appliances are manufactured with a white neutral
power supply wire and a frame connected green or bare
copper grounding wire.
Where local codes permit connecting the appliance-
grounding conductor to the neutra[ (white) wire
(US Only) (see figure 3):
1. Disconnect tile power supply.
2. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in Figure 3.
Cable from Power Supply
White Wire
(Neutral)
%
Red
Wires
Wires [
Box
Wire
(Neutral)
Ground Wire U.L-Listed Conduit
(Bare or Green Wire) Connector (or CSA listed)
Cable from appliance
Figure 3
3-WIRE GROUNDED JUNCTION BOX
__ Improper connection of aluminum
house wiring to copper leads can result in a short
circuit or fire. Use only connectors designed for
joining copper to aluminum, and follow the
manufacturer's recommended procedure dose[yo
You may not ground the oven
through the neutral (white) wire if oven is used in
a new branch circuit installation (1995 NEC), mobi[e
home, recreational vehicle, or where local codes do
not permit grounding through the neutra[ (white)
wire. When grounding through the neutra[ (white)
wire is prohibited, you must use a 4-wire power
supply cable. See Figure 4. Failure to heed this
warning may result in electrocution or other
serious personal injury.