Dewalt DCN45RND1 20V MAX 15° Cordless Coil Roofing Nailer Kit

Instructional Manual - Page 18

For DCN45RND1. Also, The document are for others Dewalt models: DCN45RN*

PDF File Manual, 60 pages, Read Online | Download pdf file

DCN45RND1 photo
Loading ...
Loading ...
Loading ...
English
16
sYMPTOM CAUsE FiX
Tool does not actuate (motor runs
but will not fire)
Low battery charge or damaged battery. Check charge level if pack shows state-of-charge. Charge or
replace battery pack if necessary.
Jammed nail/drive blade not returned to
home position.
Remove battery, clear jammed nail, cycle stall release
lever, (push driver blade up manually if necessary) reinsert
battery pack.
Damaged or worn return springs. Replace springs. Refer to Return Spring Replacement or see
authorized service center.
Damaged or worn profile. Replace profile. Refer to Replacing the Profile or see
authorized service center.
Jammed internal mechanism. See authorized service center.
Damaged internal electronics. See authorized service center.
Motor starts up but generates a
lot of noise
Jammed nail and driver blade is stuck in
down position.
Use stall release lever, clear and jammed nails, and return
driver blade manually if necessary.
Damaged or worn return springs. Replace springs. Refer to Return Spring Replacement or see
authorized service center.
Damaged or worn profile. Replace profile. Refer to Replacing the Profile or see
authorized service center.
Drive blade continues to get stuck in
down position
Jammed nail and driver blade is stuck in
down position.
Use stall release lever, clear any jammed nails, and return
driver blade manually if necessary.
Damaged or worn return springs. Replace springs. Refer to Return Spring Replacement or see
authorized service center.
Damaged or worn profile. Replace profile. Refer to Replacing the Profile or see
authorized service center.
Debris in nosepiece. Clean nose area and watch closely for small pieces of broken
nails stuck in the track.
Tool operates but does not drive
fasteners fully
Depth adjust set too shallow. Rotate depth adjust to a deeper setting.
Tool not firmly applied to workpiece. Apply adequate force to tool securing it tightly to workpiece
See instruction manual.
Material and fastener length. If the unit continues to stall (forcing the need to rotate the stall
release lever) choose the appropriate material and fastener
length that is not too rigorous of an application.
Damaged or worn profile. Replace profile. Refer to Replacing the Profile or see
authorized service center.
Damaged actuation mechanism. See authorized service center.
Tool operates, but no fastener
is driven
No nails in magazine. Load nails in magazine.
Wrong size or angle nails. Use only the recommended nails Refer to Nail Specifications.
Debris in nosepiece. Clean nose area and watch closely for small pieces of broken
nails stuck in the track.
Debris in magazine. Clean magazine.
Worn magazine. Replace magazine. See authorized service center.
Damaged or worn return springs. Replace springs. Refer to Return Spring Replacement or see
authorized service center.
Damaged or worn profile. Replace profile. Refer to Replacing the Profile or see
authorized service center.
Loading ...
Loading ...
Loading ...