INSTALLATION - 1591477A830/B
e
issue a certificate of conformity.
Adaptation to different types of gas
In case of operation with other types of gas, the
burner nozzles must be changed and the
minimum flame adjusted on the gas cocks.
Replacing nozzles
1. Remove the pan supports, burner caps and
flame-spreader crowns to access the burner
cups.
2. Replace the nozzles using a 7-mm wrench
according to the type of gas to be used (see
the “Burner and nozzle characteristics
table”).
3. Replace the burners in their respective
housings.
Adjusting the minimum setting for natural or
town gas
1. Light the burner and turn it to the minimum
position.
2. Remove the gas tap knob and turn the
adjustment screw next to the gas cock
spindle (depending on the model) until the
correct minimum flame is achieved.
3. Refit the knob and verify that the burner
flame is stable.
4. Turn the knob rapidly from the maximum to
the minimum setting: The flame should not go
out.
5. Repeat the operation on all the gas taps.
1 Extraction using a hood
2 Extraction without a hood
A Extraction with a single natural draught
chimney
B Extraction with a single chimney with
extractor fan
C Extraction directly outdoors with wall- or
window-mounted extractor fan
D Extraction directly outdoors through wall
Air
Combustion products
Extractor fan
1A1A
1B1B
2C2C
2D2D