Electrical connection
Electrical data:
Are to be found on the name plate inside the appli-
ance after removal of the lterframe.
Before undertaking any repairs, always
disconnect the extractor hood from the electricity
supply.
Length of the connecting cable: 1.30 m.
This extractor hood corresponds to EC regulations
concerning RF interference suppression.
Installation
This extractor hood is intended to be mounted
onto the kitchen wall.
Wall marking:
1. Draw a line on the wall from the ceiling to the
lower edge of the hood at the centre of the lo-
cation where the hood is going to be mounted.
2. Use the template or following the picture to
mark the points (A-C) on the wall where the
screws will be mounted.
Ensure that the minimum distance between the
hob and the extractor hood is maintained 650 mm
for the gas hob and electric hod
3. Drill ø 8 mm holes A for the extractor hood.
4 Drill ø 8 mm holes C for the chimney brackets.
5. Insert plugs 11 into the holes A,and C so that
they are ush with the wall.
6. Fix the brackets 7.2.1 using the screws sup-
plied.
7. Insert not totally the screw into the holes A.
Installation
Note: Take into account any special accessories
that are going to be tted.


Mounting the hood body
8. Before attaching the hood body, tighten the two
screws Vr located on the hood body mounting
points.
9. Hook the hood body onto the screws 12a.
10. Fully tighten the support screws 12a.
11. Adjust the screws Vr to level the hood body.
15
330
210
440
232
min. 650 Elektro/Gas*
*ab Oberkante
Topfträger
A
C