English
Status of indicator
2 LEDs (Red) light
The battery remaining
power is enough.
1 LED (Red) lights
The battery remaining
power is about half.
1 LED (Red) blinks
The battery remaining
power is nearly empty.
Recharge the battery as
soon as possible.
(5) Other functions
In case of operation error, LED lamps show as below.
Status of indicator
LED light
LED light blink in an interval.
In case of too hot
condition, Blink in
1 second interval.
In case of too cold
condition, Blink in
0.5 second interval.
After 10 seconds,
automatically turn o LED
light and Power switch.
Machine is in too cold
(below 23°F (-5°C) or too
hot condition.
Allow the nailer to cool
or warm-up thoroughly in
adequate condition.
2 LEDs blink in Orange,
after 10 seconds,
automatically turn o
Power switch.
Contact metabo HPT for
inspection
(6) How to use the LED light
While the power switch on, the LED light will
automatically light up the tip portion of the tool.
Light in green
CAUTION
Do not expose directly your eye to the light by
looking into the light.
If your eye is continuously exposed to the light,
your eye will be hurt.
Wipe o any dirt or grime attached to the lens of
the LED light with a soft cloth, being careful not
to scratch the lens.
Scratches on the lens of the LED light can result
in decreased brightness.
TESTING THE NAILER
DANGER
Operators and others in
work area MUST wear safety
glasses with side shields
which conforms to ANSI Z87.1
speci cations.
WARNING
Make sure the trigger is locked when not
ring nails.
This Nailer has a lock mechanism to prevent the
nails from being red.
Set the lock lever at the position to lock the
trigger.
Slide the lock lever to the position when the
Nailer is to be used, and to the position when it
is not in use.
000BookNT1865DMAmetabo.indb20000BookNT1865DMAmetabo.indb202018/03/1416:07:252018/03/1416:07:25