Premium Levella PIA122790A/800B 12,000 BTU Split A/C

Product Manual - Page 7

For PIA122790A/800B.

PDF File Manual, 53 pages, Read Online | Download pdf file

PIA122790A/800B photo
Loading ...
Loading ...
Loading ...
Unit
Specifications
and Features
Page 7
Achieving Optimal Performance
Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following
temperature ranges. When your air conditioner is used outside of these ranges, certain safety
protection features will activate and cause the unit to perform less than optimally.
Room
Temperature
17°-32°C (63°-90°F)
0°-30°C (32°-86°F)
10°-32°C (50°-90°F)
Outdoor
Temperature
18°-43°C (64°-109°F)
-7°-24°C (19°-75°F)
11°-43°C (52°-109°F)
-7°-43°C (19°-109°F)
(For models with low-temp cooling systems)
18°-43°C (64°-109°F)
18°-54°C (64°-129°F)
(For special tropical models)
18°-54°C (64°-129°F)
(For special tropical models)
COOL mode HEAT mode DRY mode
COOL mode
HEAT mode
DRY mode
Room Temperature
17°C - 32°C
(63°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
0°C - 50°C
(32°F - 122°F)
-15°C - 30°C
(5°F - 86°F)
0°C - 50°C
(32°F - 122°F)
0°C - 60°C
(32°F - 140°F)
(For special
tropical models)
0°C - 60°C
(32°F - 140°F)
(For special
tropical models)
-15°C - 50°C
(5°F - 122°F)
(For models with
low temp. cooling
systems.)
To further optimize the performance of your unit, do the following:
•฀Keep doors and windows closed.
•฀Limit energy usage by using TIMER ON and TIMER OFF functions.
•฀Do not block air inlets or outlets.
•฀Regularly inspect and clean air filters.
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
Inverter Split Type
Fixed-speed Type
When outside
temperature is below 0°C
(32°F ), we strongly
recommend keeping the
unit plugged in at all
time to ensure smooth
ongoing performance.
Loading ...
Loading ...
Loading ...