Loading ...
Loading ...
Loading ...
Beforecallingforservice,reviewthislist,ItmaysaveyoutimeandexpenseThislistincludescommonoccurrencesthatarenot
theresultofdefectiveworkmanshipormaterialsinthisappliance
OCCURRENCE SOLUTION
Air conditioner will not operate. Wall plug disconnected. Push plug firmly into wall outlet.
Plug Current Device Tripped. Press the RESET button.
House fuse blown or circuit breaker tripped. Replace fuse with time detay type or reset circuit breaker.
Selector Control in OFF position. Turn setector to ON (some models) or the desired FAN or COOL setting.
Unit turned off by moving thermostat to a higher number and then immediately turning back to a colder
number. Wait approximately 3 minutes. Listen for compressor to restart.
Unit turned off and then on too quickly. Turn unit off and wait 3 minutes before restarting.
Temperature setector set too low. Adjust temperature selector to higher number for cooling.
Air from unit does not feel cold
enough.
Air conditioner cooling, but
room is too warm = ice forming
on cooling coil behind decorative
front
Turn setector to a higher COOL position.
Temperature setector set too warm. Set temperature setector to colder temperature.
Room temperature betow 70°F (2t°C). Cooling may not occur until room temperature rises above
70°F (2t°C).
Temperature sensing tube touching cold coil, located behind air filter. Straighten tube away from coil
Outdoor temperature below 70 °F (21 °C). To defrost the coil, set selector to a FAN position. Then, set
thermostat to warmer position.
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set selector to FAN.
Temperature selector set too cold for night-time cooling. To defrost the coil, set selector to a FAN
position. Then, set temperature selector to warmer position.
Air conditioner cooling, but room
is too warm - NO ice forming on
cooling coil behind decorative
front.
Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.
Temperature selector set too warm. Turn temperature selector clockwise to a colder setting.
Air directional louvers positioned improperly. Position louvers for better air distribution.
Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in
front of unit.
Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.
Unit recently turned on in hot room. Allow additional time to remove "stored heat" from wails, ceiling,
floor and furniture.
Air conditioner turns on and off
rapidly.
Dirty air filter - air restricted. Clean air filter.
Outside temperature extremely hot. Set to High Cool to bring air through cooling coils more frequently.
Noise when unit is cooling,
Air movement sound. This is normal. If too loud, turn selector to lower FANsetting.
Sound of fan hitting water-moisture removal system. This is normal when humidity is high. Close doors,
windows and registers.
Window vibration - poor installation. Refer to installation instructions or check with installer.
Water dripping INSIDE when Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to
unit is cooling, installation instructions or check with installer.
Water dripping OUTSIDE when Unit removing large quantity of moisture from humid room. This is normal during excessively humid
unit is cooling, days.
Room too cold. Temperature selector set too high, set to a lower number on temperature dial.
If These Solutions Fail, Call 1-800-944-9044 For Frigidaire Service,
©2009 Electrolux Home Products, Inc, All rights reserved,
7
Loading ...