When you want to change the calculation type after entering the STAT Mode, perform
the key operation (STAT) (Type) to display the calculation type selection
screen.
Inputting Data
Use the Statistics Editor to input data. Perform the following key operation
to display the Statistics Editor:
(STAT) (Data).
The Statistics Editor provides 40 rows for data input when there is an X
column only or when there are X and Y columns, 20 rows when there are
X and FREQ columns, or 26 rows when there are X, Y, and FREQ
columns.
Note
Use the FREQ (frequency) column to input the quantity (frequency) of identical data
items. Display of the FREQ column can be turned on (displayed) or off (not displayed)
using the Stat Format setting on the setup menu.
Example 1: To select linear regression and input the following data:
(170, 66), (173, 68), (179, 75)
(STAT) (A+BX)
170 173 179
66 68 75
Important!
All data currently input in the Statistics Editor is deleted whenever you exit the STAT
Mode, switch between the single-variable and a paired-variable statistical calculation
type, or change the Stat Format setting on the setup menu.
The following operations are not supported by the Statistics Editor: ,
(M-), (STO). Pol, Rec, and multi-statements also cannot be input with the
Statistics Editor.
42