Waldorf RNLB8610GE Bold 900mm Gas Range Electric Static Oven Low Back Version

Installation Operation Manual - Page 32

For RNLB8610GE.

PDF File Manual, 37 pages, Read Online | Download pdf file

RNLB8610GE photo
Loading ...
Loading ...
Loading ...
30
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P
(20, 37).
Flue Type: A
1.
- (*) Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to information in this section for details).
Open Burner
Main Burner Injectors
Ø 2.45mm Ø 1.50mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm Ø 1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open Fully Open
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Regulator Cap Screw
Open Burner
Main Burner Injectors
Ø 2.45mm Ø 1.40mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm Ø 1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open Fully Open
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Regulator Cap Screw
Open Burner
Main Burner Injectors
Ø 2.30mm Ø 1.40mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm Ø 1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open Fully Open
Supply Pressure
20 mbar 37 mbar
Burner Operating Pressure (*)
9.5 mbar 26 mbar
Gas Regulator Cap Screw