Troubleshooting/FAQs
Q. What should I do if the Jump-N-Carry
®
will not hold a charge?
A. Load test the battery. Charge battery 24 hours before load testing. Connect a load
tester (available at your local auto parts store) to the
Jump-N-Carry
®
clamps to
check battery amperage. Depending on the model of load tester, your load testing
procedure may vary. A generic load test would bring the voltage down to 9.0 volts
and result in an amp reading of 70 amps for 6 seconds. Repeat this load test every
10 minutes for a total of three tests. If the amperage has dropped below 50 amps
on the last test, suspect a bad or weak battery.
Q. What is the ideal use for the
Jump-N-Carry
®
?
A. The
Jump-N-Carry
®
performs strongly when a vehicle’s battery needs an extra
boost because a light or radio was left on, or when a vehicle has been sitting for a
long period of time. The
Jump-N-Car
r
y
®
will star
t vehicles without any other
batteries present, but the primary use is for an extra boost.
Q. Will the
Jump-N-Carry
®
start every vehicle?
A. No. In addition to a dead battery, a car may have other mechanical problems that
would prevent the
Jump-N-Car
r
y
®
fr
om star
ting the vehicle.
Battery Replacement and Disposal
The Jump-N-Carry
®
battery may be removed by unscrewing the perimeter screws on
the back cover. Disconnect the wires from the battery terminals. Note the position of the
battery and wire locations.
Two wire connections go to each terminal.
The small wires are color coded – red for positive, black for negative.
The large cable is identified by the color of the clamp attached to the cable – red
for positive, black for negative.
Caution: It is possible for the cables to become crossed inside the case when the
battery is removed. The cables always travel straight to the battery terminals and
should never cross each other.
All red wires (red clamp) attach to the positive side of the battery. All black wires
(black clamp) attach to the negative side of the battery.
To connect a new battery, slide the battery fully into the case. Note the color of the
wires and match the color to the battery terminals.
Replace the perimeter screws on the back cover.
Charge the for 24 hours upon installation of a new battery.
The authorized replacement battery for the
Jump-N-Carry
®
JNCAIR is the Clore
PROFORMER Battery Model No. JNC105. JNC105 is a kit that includes the battery and
all necessary hardware.
Pb
This unit contains a sealed non-spillable lead-acid battery.
This battery must be recycled.
Consult your state or local
government concerning regulations for proper disposal.
Loading ...