Renogy BIFACIAL 4PCS 550 WATT SOLAR PANELS 12/24 Volt Monocrystalline PV Power Charger On/Off-Grid 2200W Supplies

Product's Documents

Below are documents related to this product, you can read online or download:

User Manual

This is the main product document for model BIFACIAL 4PCS 550 WATT SOLAR PANELS.

The file format is pdf, 24 pages, you can download this manual here .

background
Solar Panel Installation and Maintenance
Manual
Renogy
background
1. Introduction ..........................................................................................1
2. Statutes and regulations ..................................................................... 1
3. General Information ............................................................................ 2
3.1. SolarPanelIdentication ..........................................................................................................2
3.2. Junctionboxstyleandwiringmethod ..................................................................................3
3.3. GeneralSafety ............................................................................................................................. 5
3.5. OperationSafety .........................................................................................................................6
3.6. FireProtectionandSafety ........................................................................................................ 7
4. Renogy solar panels installation method .......................................... 8
4.1. Installationlocationandenvironment ...................................................................................8
4.2. Selectionofinclinationangle ................................................................................................... 8
5. Renogy solar panels installation - Mechanical installation ...........10
5.1. GeneralRequirements ............................................................................................................. 10
5.2. Mechanicalmountingofsingle-sided&double-sidedcomponents ............................. 10
5.3. Introductionofexiblemoduleinstallationmethod ......................................................... 12
6. Renogy solar panels installation - Electrical installation ..............15
6.1. Electricalparameters ............................................................................................................... 15
6.2. CableandWiring........................................................................................................................ 15
6.3. Connector
................................................................................................................................... 16
6.4. BypassDiode ............................................................................................................................. 16
7. Renogy solar panels installation - Grounding .................................17
8. Renogy solar panels installation - Operation and maintenance ...18
8.1. Solarpanelcleaning ................................................................................................................. 18
8.2. VisualInspectionofPVPanels ............................................................................................... 18
8.3. InspectionoftheConnectorandtheCable ....................................................................... 19
9. Schedule - Renogy solar panel iteration/mix recommendation .. 20
Table of Contents
background
— 1 —
1. Introduction
Firstofall,thankyouverymuchforchoosingRenogy’ssolarpanels!
WhatshouldyoudowithRenogysolarpanelinstallationandmaintenance?Thisguidehas
coveredeverythingfromsolarpanelinstallationtocleaning.
Thisguidecontainsimportantelectricalandmechanicalinstallationinformationthatyou
shouldrstunderstandbeforeyouinstallthecomponents.Inaddition,themanualcontains
someothersafetyinformationthatyoumustbefamiliarwith.Everythinginthismanualisthe
resultofalongprocessoftechnicalexplorationandexperience
Failuretofollowtherequirementsoutlinedinthismanualmayvoidthelimitedwarranty
providedtothecustomerfortheinstallationofthecomponents.Therecommendationsin
thismanualaredesignedtoimprovethesafetyofthemodulesduringinstallationandhave
beentestedandproven.PleaseprovidethismanualtotheownerofthePVsystemfortheir
referenceandinformthemofallrelevantsafety,operationalandmaintenancerequirements
andrecommendations.
2. Statutes and regulations
ThemechanicalandelectricalinstallationofPVmodulesshouldrefertotheappropriate
regulations,includingelectricalcode,buildingcodeandelectricalconnectionrequirements.
Theseregulationsvarydependingonthelocationoftheinstallation,e.g.,buildingrooftop
installation,vehicle-mountedapplications,etc.Requirementsmayalsovarywiththevoltage
oftheinstallationsystem,thenatureofthecurrent(DCorAC).Pleasecontactyourlocal
authorityforspecicterms.
background
— 2 —
3. General Information
3.1. SolarPanelIdentication
Nameplate: Type,powerratingunderstandardtestconditions,currentrating,voltagerating,
opencircuitvoltage,shortcircuitcurrent,certicationmark,maximumsystemvoltage
information.
Serial Number: Eachcomponenthasauniqueserialnumber.Thisserialnumberisprinted
onabarcode,placedinthecomponentpriortolamination,andcannotbetornorsmeared
afterlamination.Inaddition,anidenticalserialnumbercanbefoundaboveornexttothe
componentnameplate.
1.Aluminumalloyframe 2.PVGlass 3.EVA 4. Solar Cell
5.Backplate 6.Silicone 7.JunctionBox 8.Nameplate
9.CableWires 10.Connector 11.Mountingholes 12.Groundinghole
13.Leakagehole 14. Bar Code
(Therestoftheversionacorrespondingsolarpanelspecicationsshallprevail)
background
— 3 —
3.2. Junction box style and wiring method
Junction box location
Recommended connection & wiring method for series
connection
Verticalinstallation:
thestandardline
lengthcanbe(Note:
canincreasethe
extensionline)
Horizontal
installation:
standardlinelength
canbe(Note:
canincreasethe
extensionline)
Verticalinstallation:
thestandardline
lengthcanbe(Note:
canincreasethe
extensionline)
Horizontal
installation:
standardlinelength
canbe(Note:
canincreasethe
extensionline)
Junction box location
Recommended connection & wiring method for series
connection
Verticalinstallation:
thestandardline
lengthcanbe(Note:
canincreasethe
extensionline)
Horizontal
installation:
standardlinelength
canbe(Note:
canincreasethe
extensionline)
background
— 4 —
Junction box location
Recommended connection & wiring method for parallel
connection
Verticalinstallation:
thestandardline
lengthcanbe(Note:
canincreasethe
extensionline)
Horizontal
installation:
standardlinelength
canbe(Note:
canincreasethe
extensionline)
Verticalinstallation:
thestandardline
lengthcanbe(Note:
canincreasethe
extensionline)
Horizontal
installation:
standardlinelength
canbe(Note:
canincreasethe
extensionline)
Junction box location
Recommended connection & wiring method for parallel
connection
Verticalinstallation:
thestandardline
lengthcanbe(Note:
canincreasethe
extensionline)
Horizontal
installation:
standardlinelength
canbe(Note:
canincreasethe
extensionline)
Attention & Notes
Thistableisforreferenceonly,theactualwiringdependsonthe
situation,trytoreducethelengthoftheline,avoidcross-wiring.
background
— 5 —
3.3. General Safety
Whenthemodulesareinstalledontheroof,theoverallreratingofthenalstructureneeds
tobeconsidered.Also,theoverallmaintenanceafterwardsneedstobeconsidered.Foryour
safety,donotworkontheroofwithoutsafetyprecautionsincluding,butnotlimitedto,fall
protection,laddersorstairsandpersonalprotectiveequipment.Foryoursafety,donotinstall
orhandlecomponentsinhazardousenvironments,includingbutnotlimitedtostrongwindsor
gusts,wetorsandyroofs.
3.4. Electrical safety
Photovoltaicproductsgeneratedirectcurrentunderlightconditions,sotakeappropriate
protectivemeasures(insulatedgloves,insulatedshoes,etc.)toavoiddirectcontactbetween
personneland30VorhigherDCvoltages.30VorhigherDCvoltagesarepotentiallyfatal.
Componentscanalsogeneratevoltagewhennoloadorexternalcircuitisconnected.Use
insulatedtoolsandwearrubbergloveswhenhandlingthemodulesinthesun.
Photovoltaicmodulesdonothaveswitches.Themodulecanonlybemadetostopworking
bymovingthePVmoduleawayfromthelightorbycoveringitwithcloth,cardboardora
completelyopaquematerial.
Toavoidarcingandelectricshockhazards,donotdisconnectelectricalconnectionswitha
load.Incorrectconnectionscanalsocausearcingandelectricshock.Connectorsmustbe
keptdryandcleantoensuretheyareingoodworkingcondition.Donotinsertothermetal
objectsintotheconnectorsormakeelectricalconnectionsinanyotherway.
Snowandwaterorotherreectionsfromthesurroundingenvironmentcanincreasethe
intensityoftheirradiationreceivedbythemoduleandcancauseanincreaseinoutput
current.Theoutputvoltageofthemodulewillalsoincreaseappropriatelyatlowtemperatures.
background
— 6 —
Ifthemoduleglassorotherencapsulationmaterialisdamaged,wearpersonalprotective
equipmentandseparatethemodulefromthecircuit.
Touchingwetcomponentsisstrictlyforbiddenunlesswearingshockprotectionequipment
thatmeetstherequirements;whencleaningcomponents,youmustfollowtherequirements
ofthismanualforcleaningcomponents.
Theconnectormustnotcomeintocontactwiththefollowingchemicals:gasoline,white
oweroil,liveoil,moldtemperatureoil,motoroil(e.g.KV46),grease(e.g.MolykoteEM-50L,
etc.),lubricatingoil,rustpreventionoil,stampingoil,grease,dieseloil,cookingoil,acetone,
alcohol,windex,orthobonewater,tenax,moldreleaseagents(e.g.PelicoatS-6,etc.),sticky
boardadhesiveandpottingSealant(suchasKE200,CX-200,chemlok,etc.),TBP(plasticizer),
cleaningagent,etc.
3.5. Operation Safety
z
Toensurethesafetyofthecomponentsduringtransportationand
storage,unpackthecomponentsuponarrivalattheinstallationsite.
z
Protectthepackagingfromdamageordropping.
z
Itisforbiddenunderanycircumstancestolifttheentiremoduleby
graspingthejunctionboxorwires.
z
Donotstandorwalkonthemodule.
z
Donotapplyexcessiveloadsonthemoduleortwistthemoduleinorder
toavoidglassbreakage.
z
Donotdrillholesinthemodulebezel,asthiswillresultinareductionin
thebezel’sresistancetoloadandleadtocorrosionofthebezel,thereby
voidingthewarranty;
z
Donotscratchtheanodicoxidelayeronthesurfaceofthealuminum
bezel,exceptwhengroundingconnectionsaremade.Scratchingmay
leadtoframecorrosion,aectingtheframesloadresistanceandlong-
termreliability.
z
Self-repairofcomponentsisstrictlyprohibited
background
— 7 —
3.6. Fire Protection and Safety
Pleaserefertolocallawsandregulationsbeforeinstallingthecomponentsandcomplywith
themregardingbuildingreresistancerequirements.Ensureadequateventilationbetween
thebacksheetandtheinstallationsurfaceduringinstallation.Thestructureoftheroofand
thewayitisinstalledcanaecttheresafetyperformanceofthebuilding.Ifnotproperly
installed,aremayresult.Toensurethereratingontheroof,theminimumdistancebetween
themoduleframeandtheroofsurfaceis10cm.Whenmountingthemoduleontheroofofa
vehicle,ifbracketsareused,themodulemustbemountedonthebracketsandmustnotbe
tightlybondedtotheroofitself.Usepropermoduleaccessoriessuchasfuses,circuitbreakers,
andgroundconnectorsasrequiredbylocalcodes.Donotusethemoduleifthereareexposed
combustiblegasesinthevicinity.
background
— 8 —
4. Renogy solar panels installation method
4.1. Installation location and environment
Thecomponentsarenotsuitableforspaceenvironment.
Donotusemirrorsormagnifyingglassestoarticiallyfocussunlightonthemodules.
Donotinstallthemoduleinalocationwherethereisariskofwaterooding.
Itisrecommendedthatthemodulesbeinstalledinanambientoperatingtemperatureof-40°C
to40°C,whichistheaveragemonthlymaximumandminimumtemperatureattheinstallation
site.Themaximumambientoperatingtemperatureofthemoduleis-40°Cto85°C.
Ensurethatthemoduleisnotsubjectedtowindorsnowpressureexceedingthemaximum
allowableloadafterinstallation.
Themoduleneedstobeinstalledinalocationwherethereisnoshadeallyearround.Make
surethattherearenoobstaclesthatmayblockthelightatthemoduleinstallationsite.
Ifthemodulesareinstalledinalocationwherethereisfrequentlightningactivity,themodules
mustbeprotectedfromlightningstrikes.
Donotinstallandusemodulesnearamesorcombustiblematerials.
Modulesmustnotbeinstalledorusedinenvironmentssubjecttoexcessivehail,snow,sand,
soot,airpollution,soot,etc.
Componentsarestrictlyforbiddentobeinstalledontheinstallationsurfacethatissusceptible
toagingandcorrosionbytheenvironment.Forexample:wood,PVCplastic,etc.
4.2. Selection of inclination angle
Moduleinclination:Theanglebetweenthesurfaceofthemoduleandthehorizontalplane.
Whenthemoduleisfacingthesunlight,themodulewillgetthemaximumpoweroutput.
ForinstallationintheNorthernHemisphere,modulesshouldpreferablyfacesouth,andfor
installationintheSouthernHemisphere,modulesshouldpreferablyfacenorth.
Fordetailedinstallationangles,pleasefollowthestandardmoduleinstallationguidelinesor
therecommendationsgivenbyexperiencedPVmoduleinstallers.
Itisrecommendedthatthemountingangleofthemodulesbenotlessthan10degrees(RV
dependingontheactualsituation),sothatthesurfacedustofthemodulescanbeeasily
carriedawaybyrainwaterwhenitrains,thusreducingthenumberofmodulecleaning;atthe
sametime,itisconducivetotheowofwateronthesurfaceofthemodules,avoidingalarge
amountofwaterfromaccumulatingontheglassforalongperiodoftimeandleavingmarks
ontheglass,whichinturnaectstheappearanceandperformanceofthemodules.
Seriallyconnected/parallelconnectedmodulesshouldbeinstalledinthesameorientationand
angle.Iftheorientationorangleisdierent,itmaycausedierentamountofsolarradiation
receivedbyeachmodule,whichmayleadtooutputpowerloss.Toachievemaximumannual
background
— 9 —
powerproduction,theoptimalorientationandtiltofthePVmodulesintheareawheretheyare
installedshouldbeselectedtoensurethatsunlightcanstillreachthemodulesevenonthe
shortestsunnydayoftheyear.
Ifconnectedtoastand-alonePVsystem,theangleofinstallationofthemodulesshould
bebasedontheseasonandlightconditionstoobtainmaximumpoweroutput.Generally
speaking,iftheoutputofthemodulescanbemetevenonthelowestlightintensityofthe
year,thentheoutputofthemodulesatthechosenanglewillmeettheyear-rounddemand.
background
— 10 —
5. Renogy solar panels installation - Mechanical installation
5.1. General Requirements
z
PVpanelscanbeinstalledverticallyorhorizontally,andpleasekeepthedrainholesonthe
frameunblocked.
z
PleasekeepthebackboardofthePVpanelsuntouchedwithanyotherstructuresespecially
whenthereareexternalpressureonthem.
z
Pleaseleaveatleast10mmgapbetweenPVpanelsincaseofanypotentialdamagecaused
bythermalexpansionandcontraction.
z
Pleaseassuretheinstallationsite,suchastheroofofthehouseorRV,isproperlysealed
andappropriateforinstallationincaseofunexpectedproblemsandpermeating.
z
Pleaseleavea10cmclearancebetweentheframeofPVpanelsandtherooforthewallto
securetheventilationanddissipationofmoisturewhenthePVpanelsareinstalledonthe
mountingbracketsparalleltothewallortheroof.
z
PleaseensurethePVpanel(s)ismountedrmlyontheroofofthehouseorRV.
5.2. Mechanical mounting of single-sided & double-sided components
Renogycurrentlyoerscomponentsthatcanbeinstalled
mainlybythebolt-onorbracketmountingmethods.
Installationofcomponentsmustbedoneinaccordancewith
theexamplesandrecommendationsbelow.
ContactRenogypriortousingalternativemountingmethods
sinceitmayvoidthewarranty.
5.2.1. Bolt mounting method
Renogycomponentsareequippedwithcorrespondingmountingholes,thenumber&
correspondingsizearedetailedinthecorrespondingcomponentlayout;currently,theonly
mountingmethodprovidedbyourcompanyisboltmounting.Thecorrespondingbolttype/
sizediagramandthematchingmoduleversionareasfollows.
Figure2Schematicdiagramofsingle-sidedcomponentmountingholes
(Theremainingcomponentmountingholesareshowninthecorrespondingcomponent
layout)
background
— 11 —
SKU
Number per
set
Bolt
size
Pictures
Installation
schematic
Applicable
component
models
MTS-ZB 4 M6
RSP100D-BK
RNG-100D-SS
RNG-30D-SS
RNG-50D-SS
RNG-175D(Two
setsare
recommended)
RSP-200D(Two
setsare
recommended)
MTS-
ACB
4(Eachset
has2parts)
M6
RSP100D-BK
RNG-100D-SS
RNG-30D-SS
RNG-50D-SS
RNG-175D(Two
setsare
recommended)
RSP-200D(Two
setsare
recommended)
Remarks
Pleasechoosethenumberofboltsandinstallationmethodaccordingtothe
installationenvironment,conditionsandactualsituation.
5.2.2. Bolt mounting method with brackets
Renogyalsooersitscustomersanangledmountingbracketthatallowsthecustomer
tofreelyadjusttheangleofthemoduletothelightduringinstallation.Thecorresponding
mountingmethodisalsobolt-on.Themoduleisxedtothebracketbymeansofbolts.
SKU
Number of
matching
solar panels
Bolt
size
Pictures
Installation
schematic
Applicable
component
models
MTS-
TMB
1 Set for 1
panel
M6
RSP100D-BK
RNG-100D-SS
RSP80D-SS
RNG-30D-SS
RNG-50D-SS
MTS-
TM100
1 Set for 1
panel
M8
RSP100D-BK
RNG-100D-SS
RNG-50D-SS
RNG-175D
RSP-200D
RSP450D-120X2
RSP550D-144X2
RNG-320D
Remarks
Pleasechoosethenumberofboltsandinstallationmethodaccordingtothe
installationenvironment,conditionsandactualsituation.
background
— 12 —
5.2.3. Mounting method of brackets
SKU
Number of
matching
solar panels
Bolt
size
Pictures
Installation
schematic
Applicable
component
models
MTS-
SP100
1 Set for 1
panel
M8
RSP100D-BK
RNG-100D-SS
Remarks
Pleasechoosethenumberofboltsandinstallationmethodaccordingtothe
installationenvironment,conditionsandactualsituation.
5.2.4. Other installation methods
SKU
Number of
matching
solar panels
Bolt
size
Pictures
Installation
schematic
Applicable
component
models
MTS-CB
1 Set for 1
panel
/ / Allsolarpanels
Remarks
ThismountingmethodrequiresnoadditionaldrillingandissuitableforallRenogy
solarpanels.Themoduleneedstobepre-xedwithsiliconeforinstallation.
5.3.Introductionofexiblemoduleinstallationmethod
Forexiblemodules,Renogyrecommendstheuseofsiliconemountingontheroof.Theroof
shouldbecleanedbeforeinstallationtoensurethatthesurfaceisfreeofdirtandforeign
matter,andthebackofthemoduleshouldbecleanedtoensurethatthebackofthemodule
isfreeofdirtandforeignmatter.Thiswillensureastrongadhesionbetweenthebacksheet
andtheroof.Thesiliconemountingmethodiswidelyusedforexiblemodules,whichfully
combinesthemechanicalpropertiesofexiblemodulesandtoacertainextentavoids
mechanicaldamageduringsubsequentuse.
Figure3Schematicdiagramofthestructureofexiblecomponents
(Therestofthecomponentstructurediagramsarebasedonthecorresponding)
background
— 13 —
5.3.1.Introductiontoatroofmountingmethods
Aftercleaningthesurfacesofthemodules,stickdouble-sidedtapeoneachshortedgeofthe
componentforxing.Applysiliconealongthecomponenthorizontallywithawidthof6~10mm
andathicknessof3~5mm.Siliconelengthapplicationistobeadjustedaccordingtothelength
ofthecomponent,witharecommendedspacingof10mmbetweenlines.Thespacingallows
forheatdissipationandletswaterrundown.Thecomponentneedstobemountedwithin
5minutestopreventthesiliconefromcuringandaectingthebondingperformance.After
mounting,thecomponentneedstobelightlypressedalongthebondingsurfaceinthesame
directionthesiliconewasappliedusingaprofessionalpressingtool.Thedistancebetweenthe
twocomponentsbeing5~10mm.
Long side facing the direction of travel
Short side facing the direction of travel
Operating notes.
z
Whenapplyingsilicone,itisimportanttonotcompletelysealallfoursidesoftheexible
component,asthiscanaectheatdissipationanddrainage.Renogyrecommendsensuring
thatatleasttheshortedgesarenotsealedtoensureproperheatdissipationanddrainage
andtoavoidtheriskofre.
z
Thenumberofhorizontalsiliconeglueapplicationscanbeadjustedaccordingtopersonal
preference.Renogyrecommendsapplyinggluetotheedgeofthedouble-sidedtapewitha
widthof6-10mmandathicknessof3-5mm.
z
Double-sidedadhesivetapeshouldbeushwiththeedgeasmuchaspossible.
background
— 14 —
z
Aftertheinstallationiscompleted,itshouldbeleftfor72Htoensurethatthesiliconeisfully
cured,avoidingdirectsunlight,rainandotherharshweatherduringthecuringperiod.
z
Themaximumbendoftheexiblemodulecanreach240°,butthisbendisforthe
convenienceofstorage,theactualinstallationisrecommendedtoinstalltheexible
modulehorizontally,ortheinstallationbendislessthan30°toensurepowergeneration
eciency.
z
Whenashortedgeisusedasthebendingedge,thebendinganglemustnotexceed30°.
Sunlight
Components are fully illuminated Flexible Photovoltaic Modules
Fully sunlit area
PV
Components are fully illuminated
PV
Note:Astheinstallationanglebecomesmorecurved,thenon-illuminatedareaofthemodule
willincrease.Whenthebendingradiusexceeds30degrees,thenon-illuminatedareaofthe
modulewillexceed30%,whichwillaecttheoutputofthemodule.
5.3.2.Introductiontonon-atroofmountingmethods
Aftercleaningtheexiblemodules,stickdouble-sidedtapeoneachlongedgeofthe
componentforxing.Applythesiliconeaccordingtothewidthofthecorrugatedroof
protrusion;installthecomponentwithin5minutesafternishingthesiliconeapplicationto
preventthesiliconefromcuringandaectingthebondingperformance.Useaprofessional
pressingtoolandlightlypressthesurfaceofthecomponentalongthedirectionofgluing.The
distancebetweenthetwocomponentsis5~10mm.
Aftertheinstallationofthesiliconepartiscompleted,theexiblecomponentcanbefurther
xedbyapplyingboltsaccordingtothemountingholesthatcomewiththeexiblecomponent
itself.
Silicone position
Figure 3: Non-flat gluing diagram Figure 4: Schematic diagram of
flexible component mounting holes
Note:Renogyrecommendsthatnon-atroofneedtomeetaminimumof6siliconelineson
thebackside,ifthisconditionisnotmet,theexiblemoduleisnotsuitableforthisroof.
background
— 15 —
6. Renogy solar panels installation - Electrical installation
6.1. Electrical parameters
Thenominalvaluesofelectricalperformanceparametersforcomponents,suchasIsc,Voc,
andPmax,areobtainedunderstandardtestconditions.Thestandardtestconditionsfor
componentsincludeanirradianceof1000W/m2,celltemperatureof25°C,andairmassAM1.5.
Whencomponentsareconnectedinseries,theVocofthecombinationisthesumoftheVoc
valuesofindividualcomponents,andtheIscremainsthesameasthatofasinglecomponent.
Whencomponentsareconnectedinparallel,theVocisthesameasthatofasingle
component,andtheIscisthesumoftheIscvaluesofmultiplecomponents.Refertothegure
below.Itisnotrecommendedtoconnectcomponentswithdierentparameters,models,or
brandsinseriesorinparallel.
Themaximumnumberofcomponentsthatcanbeconnectedinseriesdependsonthe
maximumsystemvoltagesupportedbythecomponent.Afterbeingconnectedinseriesunder
thelowestlocaltemperatureconditions,theopencircuitvoltagecannotexceedthemaximum
systemvoltagevaluespeciedbythecomponent,suchasDC600V/DC1000V/DC1500V.In
practicalapplications,thenumberofcomponentsconnectedinseriesandparallelneedstobe
designedaccordingtotheparametersandmodelsofthecomponentsandcontrollers.
Theopencircuitvoltagecorrectionfactorcanbecalculatedusingthefollowingformula:
CVoc=1-
β
Voc×(25-T).Tistheexpectedminimumambienttemperatureatthesystem
installationlocation,and
β
(%/°C)isthetemperaturecoecientoftheselectedcomponent
Voc(refertothecorrespondingcomponentparametertable).
Iftheremaybereversecurrentpassingthroughthecomponentthatexceedsthemaximum
fusecurrentofthecomponent,thesamespecicationovercurrentprotectiondevicemustbe
usedtoprotectthecomponent.Ifthenumberofcomponentsconnectedinparallelisgreater
thanorequalto2inaseries,theremustbeanovercurrentprotectiondeviceoneachseries
component,asshowninthegureabove.
6.2. Cable and Wiring
6.2.1 Introduction of cables and connections
Renogymodulesuseajunctionboxwithaprotectionratingforconnections(seemodule
specicationfordetails)toprovidesafeprotectionforthewiringanditscorresponding
connectionsandaccessibleprotectionfornon-insulatedliveparts.Thejunctionboxconsists
ofconnectedcablesandconnectorswithcorrespondingprotectionratings,whichfacilitate
theseries/parallelconnectionofmodules.Eachindividualmodulehastwowiresconnectedto
thejunctionbox,onepositiveandonenegative.Theconnectionofthepositiveandnegative
polesofthemodulescanbeachievedthroughtheMC4connectors.
background
— 16 —
Specialsolarcablesandappropriateconnectorsshouldbeusedinaccordancewithlocal
re,building,andelectricalregulations(thewiresshouldbecoveredbyaging-resistant
conduits,andifexposedtoair,shouldhaveaging-resistantproperties),andtheelectricaland
mechanicalpropertiesofthecablesshouldbeensured.
Afterthecableisinstalledandconnected,itshouldbeprotectedfrommechanicaldamage.Do
notpressthecabletoohard.Althoughthecableisresistanttoagingandwaterproof,itshould
alsobeprotectedfromdirectsunlightandrain.Theminimumbendingradiusofthecable
shouldbe43mm.
6.2.2 Extension cable selection for component-to-component connection
Renogycurrentlyprovidescustomerswithinter-moduleconnectioncablesmainlyintheform
ofSKU:RNG-EXTCB,withawirediameterspecicationof10/12AWG,andamaximumlengthof
40FTforextensioncables.
6.2.3 Extension cable for connecting the component to the controller
Renogycurrentlyprovidescustomerswithconnectioncablesbetweenmodulesand
controllersmainlyintheformofSKU:RNG-AK,withawirediameterspecicationof10/12AWG,
andamaximumlengthof40FTforextensioncables.
6.3. Connector
Pleasekeeptheconnectorsdryandclean,andensurethatthenutoftheconnectorisina
tightenedstatebeforeconnecting.Donotconnecttheconnectorsiftheyarewet,dirty,orin
anyotherunfavorablecondition.Iftheconnectorsarenotconnectedpositivelyandnegatively,
theydonothavewaterprooffunction.Afterinstallingthemodules,theyneedtobeconnected
assoonaspossibleorappropriatemeasuresneedtobetakentoavoidtheinltrationof
watervaporanddust.Avoiddirectsunlightandimmersioninwaterfortheconnectors.Avoid
theconnectorsfallingonthegroundorontheroof,causingparticlesordusttoenterthe
connectorsandaectingsubsequentuse.Incorrectconnectionsmayproducearcsand
electricshocks.Pleaseensurethatallelectricalconnectionsaresecure.Makesurealllocked
connectorsarefullyconnected.Itisnotrecommendedtousedierenttypesofconnectors
together.
6.4. Bypass Diode
Thesolarcellsinthesolarmoduleareconnectedinserieswithabypassdiodeparallel
protection,whichisencapsulatedinthejunctionbox.Whenahotspotphenomenonoccurs
inamodule,thediodewillstartworkingtopreventthemaincurrentfromowingthroughthe
hotspotcell,therebylimitingtheheatingandperformancelossofthemodule.Notethatthe
bypassdiodeisnotanovercurrentprotectiondevice.Ifthediodeissuspectedorconrmedto
befaulty,pleasecontactRenogy.Itisstrictlyprohibitedtoattempttoopenthejunctionboxof
themoduleonyourown.
background
— 17 —
7. Renogy solar panels installation - Grounding
Thedesignofthemoduleusesanodized,corrosion-resistantaluminumalloyframesasrigid
support.Inordertoensuresafeuseandpreventdamagefromlightningandstaticelectricity,
themoduleframemustbegrounded.Whengrounding,thegroundingdevicemustbeinfull
contactwiththealuminumalloyinterior,penetratingtheoxidelmonthesurfaceofthe
frame.Itisstrictlyforbiddentoaddanyadditionalgroundingholesonthemoduleframe.The
groundingconductororgroundingwirecanbemadeofcopper,copperalloy,oranyother
materialthatmeetstherequirementsofthecorrespondingnationalelectricalspecicationsas
aconductor.Thegroundingconductormustbeconnectedtotheearththroughanappropriate
groundingelectrode.Theholesmarkedwiththegroundingsymbolontheframecanonlybe
usedforgroundingandnotformoduleinstallation.Formoduleswithoutgroundingholes,they
canbegroundedbyconnectingthemtoagroundedelectricaldevice.
background
— 18 —
8. Renogy solar panels installation - Operation and maintenance
Itisrequiredtoperformregularinspectionandmaintenanceofthemodules,especiallyduring
thewarrantyperiod.PleasecontactRenogyin2weeksifanyabnormalityordamageisfound.
8.1. Solar panel cleaning
Theaccumulationofforeignsubstances(suchasdustandbirddroppings)ontheglass
surfaceofsolarpanelscanaecttheirpoweroutputandevencausehotspotsinthearea.
Theextentoftheimpactdependsonthetransparencyoftheforeignmaterial.Forexample,a
smallamountofdustontheglasssurfacecanaecttheintensityanduniformityofabsorbed
sunlight,thisusuallydoesnotcausedamagetothesolarpanel,andthepoweroutput
usuallydoesnotdecreasesignicantly.However,alargeamountofdustaccumulation,bird
droppings,andshadingbyplantscanformobstructions,whichcansignicantlyreducepower
outputandevenformhotspots.Itisrecommendedthatthesurfaceofthepanelsshouldnot
beobstructedbyanythingwhenthereissunlight.
Thecleaningfrequencydependsonthehowmuchforeignmatteranddebrisaccumulates.
Inmanyinstancesthefrontsubstrategetscleanedwiththerain,andyoucandecreasethe
cleaningfrequency.Itisrecommendedtowipetheglasssurfacewithwetspongeorsoftcloth.
Pleasedonotcleantheglasswithcleaningagentwhichcontainsacidoralkali.
Toavoidpotentialelectricalshockorburn,pleasecleanthePVpanelsintheearlymorningor
atdusk.DonotcleanthePVpanelswithdamagetotheglasssurface,backboardorwires.
8.2. Visual Inspection of PV Panels
InspectthePVpanelsvisuallytondifthereareappearancedefect,especially:
z
Iftheglassisbroken;
z
Corrosionalongthecells’busbar.Thecorrosioniscausedbymoisturethathasinltrated
intothemoduleswhenthesurfaceencapsulationmaterialdamagedduringtheinstallation
ortransportation.
z
Ifthereisevidenceofburningonthepanel.
z
Checktheencapsulationoftheconnectorwiththecable.
z
EnsurethePVpanelsareuntouchedwithsharpobjects.
z
EnsurethePVpanelsarenotshaded.
z
ChecktheconnectionbetweenthePVpanelsandthemountsandbrackets.
background
— 19 —
8.3. Inspection of the Connector and the Cable
It’srecommendedtoimplementthefollowingpreventivemaintenanceevery6months:
z
ChecktheconnectionsbetweenthePVpanelsandothero-gridcomponents.
z
Checkthesealinggelofthejunctionboxtoensureifitiscrackorcrevice.
background
— 20 —
9. Schedule - Renogy solar panel iteration/mix recommendation
SKU Versions Size/mm
Mounting
hole number
& size
Recommended
number of
mounting holes
Mixable
versions
RNG-10D-SS G1 341x266 4-10*7 4 /
RNG-30D-SS G1 570x341 4-10*7 4 /
RNG-50D-SS G1 601x498 4-10*7 4 G1/G2/G3
RNG-50D-SS G2 581x509 4-10*7 4 G1/G2/G3
RNG-50D-SS G3 578x503 4-7*11 4 G1/G2/G3
RNG-80D-SS G1 920x498 20-14*9 4 G1/G2
RNG-80D-SS G2 938x509 20-14*9 4 G1/G2
RNG-100D-SS G1 1074x798 20-14*9 4 G1/G2/G3
RNG-100D-SS G2 1076x509 20-14*9 4 G1/G2/G3
RNG-100D-SS G3 1062x530 20-14*9 4 G1/G2/G3
RNG-100MB G1 1038x533 20-14*9 4 /
RSP100D-BK G1 1100x509 20-14*9 4 G1/G2
RSP100D-BK G2 1062x530 20-14*9 4 G1/G2
RNG-175D G2 1262x699 20-14*9 4 G1/G2
RNG-175D G1 1328x670 20-14*9 4 G1/G2
RSP200D G3 1491x699 20-14*9 4 G1/G2/G3
RSP200D G2 1650x670 20-14*9 4 G1/G2/G3
RSP200D G1 1620x657 20-14*9 4 G1/G2/G3
RNG-320D G1 1665x1002 4-14.5*6.5 4 G1/G2
RNG-320D G2 1665x1002 4-14.5*6.5 4 G1/G2
RSP450D-120 G1 1909x1134 8-14*9 4 /
RSP550D-144 G1 2279x1134
8-14*9;
4-11*7
4 /
RNG-10DB-H G1 481x301
6-Inner
φ
8;Outer
φ
14
6 G1/G2
RNG-10DB-H G2 481x301
6-Inner
φ
8;Outer
φ
14
6 G1/G2
RNG-50DB-H G1 673x508
6-Inner
φ
6;Outer
φ
11
4 G1/G2/G3
RNG-50DB-H G2 683x508
6-Inner
φ
6;Outer
φ
11
4 G1/G2/G3
background
— 21 —
SKU Versions Size/mm
Mounting
hole number
& size
Recommended
number of
mounting holes
Mixable
versions
RNG-50DB-H G3 712x460
6-Inner
φ
6;Outer
φ
11
4 G1/G2/G3
RNG-100DB-H G1 1219x546
6-Inner
φ
6;Outer
φ
12
6 G1/G2/G3
RNG-100DB-H G2 1219x546
6-Inner
φ
6;Outer
φ
12
6 G1/G2/G3
RNG-100DB-H G3 1093x582
6-Inner
φ
6;Outer
φ
11
6 G1/G2/G3
RSP100DL-36 G1 1093x582
6-Inner
φ
6;Outer
φ
11
6 /
RNG-175DB-H G1 1504x673
6-Inner
φ
6;Outer
φ
12
6 G1/G2
RNG-175DB-H G2 1504x673
6-Inner
φ
6;Outer
φ
12
6 G1/G2
RSP200DB-72 G1 1605x748
6-Inner
φ
6;Outer
φ
11
6 /
background
RENOGY.COM
Renogy aims to empower people around the world through education and distribution of DIY-friendly renewable
energy solutions.
Renogy Power Plus allows you to stay in the loop with upcoming solar energy innovations, share your experiences
with your solar energy journey, and connect with like-minded people who are changing the world in the Renogy
Power Plus community.
We intend to be a driving force for sustainable living and energy independence.
In support of this eort, our range of solar products makes it possible for you to minimize your carbon footprint
by reducing the need for grid power.
Renogy Empowered
Live Sustainably with Renogy
Did you know? In a given month, a 1kW solar energy system will...
Save 170 pounds of coal from being burned
Save 300 pounds of CO2 from being released into the atmosphere
Save 105 gallons of water from being consumed
@Renogy Solar @Renogy@renogyoicial
Renogy Power
PLUS
Renogy reserves the right to change the contents of this manual without notice.

Specifications