Loading ...
Loading ...
Loading ...
18
English
2
If nails are driven too deep, turn the adjuster to the
shallow side.
Adjustments are in half-turn increments.
2
Too Deep
Turn Adjuster
Flush
If nails are driven too shallow, turn the adjuster to the
deep side.
Turn Adjuster
Flush
2
Too Shallow
3
Stop turning the adjuster when a suitable position is
reached for a nailing test.
4
Connect the air hose.
ALWAYS WEAR EYE PROTECTION.
Perform a nailing test.
5
DISCONNECT AIR HOSE FROM NAILER.
6
Choose a suitable position for the adjuster.
USING THE NOSE CAP
WARNING
Disconnect the air hose from the nailer
before attaching or removing the nose cap.
If you like to protect the surface of workpiece against
scratches or markings made by the push lever, attach the
accessory nose cap to the push lever.
1
DISCONNECT AIR HOSE FROM NAILER.
2
Put the nose cap to the toe of the push lever.
NOTE:
The nose cap may reduce nailing depth due to its
thickness. Re-adjustment of nailing depth is required.
1
Push Lever
Nose
Hole
Protrusion (Inward)
Do not connect
air hose
Nose Cap
Nose cap can be removed from the push lever using a
screwdriver or thin rod.
Nose cap
Screwdriver
Push lever
Nose cap can be stored on the magazine as shown below.
Nose cap
Magazine
000BookNV90AG(S)metabo.indb18000BookNV90AG(S)metabo.indb182018/03/1915:58:422018/03/1915:58:42