Loading ...
Loading ...
Loading ...
9
EN
INSTALLATION
Electrical Data
Power cord may include a current interrupter
device. TEST and RESET buttons are provided
on the plug case. The device should be tested on
a periodic basis by frist pressing the TEST button
and then the RESET button. If the TEST button
does not trip or if the RESET button will not stay
engaged, discontinue use of the air conditioner
and contact a qualified service technician.
for 120 V
Use Wall Receptacle Power Supply
Standard 120 V, 3-wire
grounding receptacle rated
15 A / 120 VAC / 60 Hz
Use 15 A, time
delay fuse or 15 A,
circuit breaker.
WARNING
This appliance should be installed in
accordance with the National Electrical Code.
Use of extension cords could cause serious
injury or death.
Do not use an extension cord with this
window air conditioner.
Do not use surge protectors or multi-outlet
adapters with this window air conditioner.
Never push the TEST button during operation.
Doing so can damage the plug.
Do not remove, modify, or immerse this
plug. If this device trips, the cause should be
corrected before further use.
CAUTION
The conductors inside this cord are surrounded
by shields, which monitor leakage current.
These shields are not grounded. Periodically
examine the cord for any damage. Do not
use this product in the event the shields
become exposed. Avoid shock hazard. This
unit cannot be user-serviced. Do not open the
tamperresistant sealed portion. All warranties
and performance will be voided. This unit is not
intended to be used as an ON/OFF switch.
Loading ...
Loading ...
Loading ...