29INSTALLATION
ENGLISH
NOTE
If any leaks are found, shut off the water faucet,
remove the hose and check the condition of the
rubber seal.
Final Installation Check
Once you have completed the installation of the
dryer and it is in its final location, confirm proper
operation with the following tests.
Test Dryer Heating
Gas Models
Close the dryer door and press the Power button
to turn the dryer on. Press the Time Dry and
Start/Pause buttons to start the test. When the
dryer starts, the igniter should ignite the main
burner.
NOTE
If all air is not purged from the gas line, the gas
igniter may turn off before the main burner
ignites. If this happens, the igniter will reattempt
gas ignition after approximately two minutes.
Electric Models
Close the dryer door and press the Power button
to turn the dryer on. Press the Time Dry and
Start/Pause buttons to start the test. The exhaust
air should be warm after the dryer has been
operating for 3 minutes.
Checking Airflow
Effective dryer operation requires proper airflow.
The adequacy of the airflow can be measured by
evaluating the static pressure. Static pressure in
the exhaust duct can be measured with a
manometer, placed on the exhaust duct
approximately 2 ft. (60.9 cm) from the dryer. Static
pressure in the exhaust duct should not exceed 0.6
inch (1.5 cm). The dryer should be checked while
the dryer is running with no load.
Checking Levelness
Once the dryer is in its final location, recheck the
dryer to be sure it is level. Make sure it is level front
to back and side to side, and that all four leveling
feet are in firm contact with the floor.
Test Exhaust System
Once you have completed the installation of the
appliance, use this test to make sure the condition
of the exhaust system is adequate for proper
operation of the appliance. This test should be
performed to alert you to any serious problems in
the exhaust system of your home.
Your appliance features Flow Sense
TM
, an
innovative sensing system that automatically
detects blockages and restrictions in dryer
ductwork. Keeping ductwork clean of lint
buildup and free of restrictions allows clothes to
dry faster and reduces energy use.
NOTE
The appliance should be cool before starting this
test. If the appliance was warmed up during
installation, run the Air Dry cycle for a few
minutes to reduce the interior temperature.
Activating the Installation Test
1 Remove the drying rack and literature, and
then close the door.
Do not load anything in the drum for this
test, as it may affect the accuracy of the
results.
2 Press and hold the More Time and Damp Dry
Signal buttons and then press the Power
button.
On models with a glass touch control panel,
press the Power button then IMMEDIATELY
press and hold the More Time and Damp
Dry Signal buttons.
Loading ...
Loading ...