Actions required to prevent frost
(Water Removal in Water Tank and Evaporator)
If the ambient temperature falls below 0°C/32
o
F, water will freeze inside the machine and machine
operation will be impossible.
If not use in for a long period of time in the winter, be sure to completely remove the water inside the
body by following the instructions below. If you do not remove the water or if it is insufficient, it will cause
serious damage to the product. This shall not be guaranteed by the manufacturer and may result in
repair costs. Please observe the following points.
1. Turn on the power switch and press the DOWN + SET
button at the same time for 3 seconds with any signal
on the FND window. Forced drainage will be done for
30 seconds.
2. Turn off the power switch and disconnect the power
plug from the outlet.
3. Remove the upper panel → the front panel.
4. Remove the evaporator cylinder drain hose clamp
and remove the hose, and wait until the ice in the
evaporator cylinder completely melts down. It is
possible to remove internal water quickly by using
compressed air gun etc.
5. Reassemble the evaporator cylinder drain hose
and tighten the clamp.
6. Assemble in the order of left panel → upper
panel → front panel.
AIWD450: back panel upper panel
Emptying the drainage gutter (AIWD450)
When the water in the front drain is full, a white float comes up, so empty out the drain and
pour water.
(If water overflows, it may flow onto the floor, so empty it from time to time).