OPERATION
The fireplace can be operated either by the switches located on the left bottom of the fireplace unit
or by supplied remot e cont rol.
Plug the fireplace into a 15 Amp wall socket .
M ANUAL OPERATION
1. The main power ON/ OFF swit ch in position O, the fireplace is OFF.
2. When main power ON/ OFF switch is at posit ion I, the fireplace is ready to use.
3. Press the
butt on repeat edly to set the heat er to desired heat set t ing. The heater indicator
LED will glow which show s the current heater settings.
a)RED 1465W HEAT OUTPUT
b)BLUE 750W HEAT OUTPUT
c)PURPLE AUTO M ODE
AUTO M ODE
Under this mode t he heat er will aut omatically t urn ON at high heat setting 1465W heat output w hen
the room temperature drops below 22(72 ). When t he room temperature is bet w een
22-25(72-77) the heat er output will swit ch to low heat setting 750W. When the r oo m
temperat ur e goes above 25(77) the heat er will be turned off and the cycle will continue. The
LED indicator will be PURPLE in colour under this mode.
4. Flame effect: Press the button marked
to adjust the flame brightness. The flame bright ness
will cycle through Low -M edium-High -OFF.
5. M ood light effect: Press the button marked
to change the mood light colour.
NOTE: If operated at the Low heat setting, the fireplace will not provide as much heat out put as in
the High heat setting, however the low set t ing will not require as much electrical pow er to operate.
To avoid overloading a circuit, do not plug the fireplace into a circuit that already has ot her
appliances working. When the fireplace is not in use swit ch off and unplug.
SAFETY CUT-OFF
l This appliance is fitt ed wit h a safety cut-off which will operate if the fireplace overheats (eg. Due
to blocked air vent s). For safet y reasons, the fireplace will NOT aut omatically reset.
l To reset the appliance, disconnect the appliance from the main supply for at least 10 minut es.
Reconnect the supply to the main and switch on the appliance.