4. Renogy solar panels installation method
4.1. Installation location and environment
Thecomponentsarenotsuitableforspaceenvironment.
Donotusemirrorsormagnifyingglassestoarticiallyfocussunlightonthemodules.
Donotinstallthemoduleinalocationwherethereisariskofwaterooding.
Itisrecommendedthatthemodulesbeinstalledinanambientoperatingtemperatureof-40°C
to40°C,whichistheaveragemonthlymaximumandminimumtemperatureattheinstallation
site.Themaximumambientoperatingtemperatureofthemoduleis-40°Cto85°C.
Ensurethatthemoduleisnotsubjectedtowindorsnowpressureexceedingthemaximum
allowableloadafterinstallation.
Themoduleneedstobeinstalledinalocationwherethereisnoshadeallyearround.Make
surethattherearenoobstaclesthatmayblockthelightatthemoduleinstallationsite.
Ifthemodulesareinstalledinalocationwherethereisfrequentlightningactivity,themodules
mustbeprotectedfromlightningstrikes.
Donotinstallandusemodulesnearamesorcombustiblematerials.
Modulesmustnotbeinstalledorusedinenvironmentssubjecttoexcessivehail,snow,sand,
soot,airpollution,soot,etc.
Componentsarestrictlyforbiddentobeinstalledontheinstallationsurfacethatissusceptible
toagingandcorrosionbytheenvironment.Forexample:wood,PVCplastic,etc.
4.2. Selection of inclination angle
Moduleinclination:Theanglebetweenthesurfaceofthemoduleandthehorizontalplane.
Whenthemoduleisfacingthesunlight,themodulewillgetthemaximumpoweroutput.
ForinstallationintheNorthernHemisphere,modulesshouldpreferablyfacesouth,andfor
installationintheSouthernHemisphere,modulesshouldpreferablyfacenorth.
Fordetailedinstallationangles,pleasefollowthestandardmoduleinstallationguidelinesor
therecommendationsgivenbyexperiencedPVmoduleinstallers.
Itisrecommendedthatthemountingangleofthemodulesbenotlessthan10degrees(RV
dependingontheactualsituation),sothatthesurfacedustofthemodulescanbeeasily
carriedawaybyrainwaterwhenitrains,thusreducingthenumberofmodulecleaning;atthe
sametime,itisconducivetotheowofwateronthesurfaceofthemodules,avoidingalarge
amountofwaterfromaccumulatingontheglassforalongperiodoftimeandleavingmarks
ontheglass,whichinturnaectstheappearanceandperformanceofthemodules.
Seriallyconnected/parallelconnectedmodulesshouldbeinstalledinthesameorientationand
angle.Iftheorientationorangleisdierent,itmaycausedierentamountofsolarradiation
receivedbyeachmodule,whichmayleadtooutputpowerloss.Toachievemaximumannual