4
11
Ensure the supplied rubber
washer is fitted inside the
coupling.
Tighten coupling
with spanner.
180
No leaks!
Plumbing -- Wa
ter inlet connection
IMPORTANT!
The appliance
should be connected to the water main using the new water
inlet hose supplied. Old hoses should not be used.
Do not shorten the inlet hose.
1.Take note of water connection requirements.
The dishwasher has a single valve water connection.
We recommend a cold water connection for best performance and energy efficiency.
The incoming water temperature should not exceed 60

2.Take note of the permitted water pressure extremes.
Lowest: 0.3 bar = 3 N/cm = 30kPa
Where pressure is below 1 bar, contact a qualified plumber.
Highest: 10 bar = 100 N/cm = 1MPa
Where pressure is above 10 bar, a pressure reduction valve must be installed.
Contact a qualified plumber.
3.Connect the water inlet hose to an accessible water tap with a “3/4” BSP connector.
Ensure that there is no kink in the inlet hose that could restrict the flow of water. A
90
o
bend requires a minimum height of 20
0mm for a kink-free curve.
Ensure incoming water is clear. If the water pipes have not been used for a long
period of time, let the water run to make sure it is clear with no impurities. Not
doing so may result in the water inlet hose getting blocked and damaging the appliance.
If required, use a filter insert to filter out deposits from the piping. The filter insert is
available from your Authorised Service Centre or Customer Care.
4.Tighten the hose coupling a further half turn after seal contact.
5.Check that the connection does not leak.
min.
10mm
“3/4” BSP connector
Connect inlet hose to cold water
Installation instructions