_ Installation Instructions Split System Condensers I
See Figures 5 thru 8 and Wiring Diagram on unit.
Use of Rigid Metal Conduit
It is recommended that wires be tied together or twisted to-
gether inside the conduit. This will minimize any buzzing
type sounds that could be produced with high current
loads, such as during starting. Under some conditions it
may be necessary to use a hard start kit to eliminate prob-
lem noises.
Figure5
A/C Control Box
Contactor
Ground Lug
Wires
(Low Voltag e)
Line Voltage
Entrance
Low Voltage
Entrance
Control Box Access
Remove the four screws. Cover is notched so it will slide
out from under top edge of unit.
Figure 6 Heat Pump Control Box
Figure 7|'" " A/C Condenser Typical Low
I Voltage Connections
Indoor
Thermostat
R G BL
! I I
(Compressor
W
!
(Co
Outdoor
Unit
:ontactor)
_. Y--
INDOOR
BLOWER
COIL
GAS
OR FURNACE
Defrost
Control
Contactor
Ground Lug
Line Voltage
Entrance
Low Voltage
Entrance
Pigtail Wires
(Low Voltage)