Method two (Mounting under a Cupboard):
1) The rangehood must be placed at a minimum distance of 65cm from the cooking surface. The maximum
distance should be 75cm for best effect Drill 4 holes of Ø 6mm at the bottom of the hanging cupboard.
2) Drill six Ø4mm holes at the bottom of the cupboard. Cut a minimum Ø120mm hole for the outlet venting (if
required).
3) Put the one-way valve on the rangehood (if required), then install the rangehood onto the bottom of the
cupboard, tighten the hood with enclosed 6 screws (M4*35mm).
4) Install the adjusted board on the bottom of the hood in order to keep out the gap between hood back and
cupboard.
ORF60X ORF90X
Recirculating or Ducted Venting:
The rangehood can be installed to vent the exhaust fumes
out of the room (ducted) or to recirculate the air back into
the room once it has been filtered (recirculating). To set
the rangehood up to vent the exhaust fumes out of the
room, adjust the venting switches (internal between the
fans) to ducted and connect appropriate ducting to the
one way valve.
To set the rangehood up to vent back into the room,
remove the vent cover from the front of the rangehood and
adjust the venting switch to recirculating. Note that carbon
filters must also be fitted to the fan inlets as shown.
OPERATING INSTRUCTIONS
The controls are at the bottom front of the rangehood.
LIGHT CONTROLS:
Use switch 1 to turn the lights on (I) or off (0).
SPEED ADJUSTMENT:
Use switch 2 to adjust the fan speed from low (I) to high (III), and turn off (0).
NOTE: Always fully extend the slide-out when in use.