6
EN
www.napoleongrills.com
N415-0434 DEC 19.18
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and
piping should be located as shown in the built-in instrucons. A exible metal connector is included to
simplify the installaon of the unit. Connect this connector to the are ng on the end of the manifold.
Connect the other end of the connector to the gas piping. Ensure that the connector does not pass
through a wall, oor, ceiling or paron, and is protected from damage. Do not use a hose to connect the
unit. It must be connected with rigid pipe, copper tube or an approved exible metal connector which
complies with Z21.4 /CSA 6.10 or ANSI Z21.75/CSA 6.27.
The installaon must comply with CAN B149.1 Natural Gas and Propane Installaon Code in Canada, or
to the Naonal Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently
sized to supply the BTU/h specied on the rang plate, based on the length of the piping run. If installing
a side burner, a separate line must be branched o to the side burner unit and enter the side burner
opening at the specied locaon.
WARNING! Built in units are supplied with a drip pan which holds only a minimal amount of
grease. To prevent grease res, the pan must be cleaned aer each use.
WARNING! Access must be provided to the inside of the enclosure to make gas connecons.
DANGER! Read all instrucons carefully before operang the grill. Failure to follow these
instrucons exactly could result in a re causing serious injury or death. The enre installaon must be
leak tested before operang the grill.
!
!
Leak Tesng Instrucons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames
are in the area while you check for leaks. Sparks or open ames will result in a re or explosion,
damage to property, serious bodily injury, or death.
Leak tesng: This must be done before inial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak
Tesng Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Soluons department and have the grill inspected by a cered
gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill
inspected by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.
!
!
STOP
N415-0434 DEC 19.18.indd 6 12/19/2018 2:07:56 PM