12
together. Adhere the duplicate data plate to an
accessible location near the hotplate. When satisfied with
the hotplate, please instruct the user on the correct
method of operation. In case the appliance fails to
operate correctly after all checks have been carried out,
refer to the authorised service provider in your area.
It should be expressly noted that we cannot accept any
liability for direct or indirect damage caused by wrong
connection, leakage or improper installation. When being
repaired, the appliance must always be disconnected
from the mains supply; if required, notify our customer
service.
Converting the
cooktop from Nat.
Gas to Universal LPG
To change injectors All work involved in installation, setting and adaptation to
a different gas type must be carried out by authorised
personnel from our Service Centre and must comply with
current regulations and the conditions laid down by the
local gas company.
Request change-over injectors from our customer service
deparment (refer injector chart below for sizes).
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
Natural Gas Universal LPG
Burner Hourly Gas
Consumption
(MJ)
Injector
mark
Hourly Gas
Consumption
(MJ)
Injector
mark
(mm)
Auxiliary 3,60 90 3,50 50
Semi-rapid 6,50 118 6,00 67
Rapid 10,80 155 10,00 85
Double
flame
12,00 160 11,00 91
Triple flame 16,00 182 13,50 100
Loading ...
Loading ...