Blue Seal Evolution G56D Series 900mm Gas Range Convection Oven

Installation Operation Manual - Page 26

For G56D.

PDF File Manual, 32 pages, Read Online | Download pdf file

G56D photo
Loading ...
Loading ...
Loading ...
24
- Australia:
- New Zealand):
- (*) Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to information in this section for details).
Open Burner
Main Burner Injectors
Ø 2.45mm Ø 1.50mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm Ø 1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open Fully Open
Main Burner
Ø 2.60mm Ø 1.60mm
Oven
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open Fully Open
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Regulator Cap Screw
Open Burner
Main Burner Injectors
Ø 2.45mm Ø 1.40mm
Pilot Burner ('PF' Option Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm Ø 1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open Fully Open
Main Burner
Ø 2.60mm Ø 1.60mm
Oven
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully Open Fully Open
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Regulator Cap Screw
Loading ...
Loading ...
Loading ...