Waldorf RNB8826G Bold 1200mm Gas Range Static Oven

Installation Operation Manual - Page 6

For RNB8826G.

PDF File Manual, 29 pages, Read Online | Download pdf file

RNB8826G photo
Loading ...
Loading ...
Loading ...
4
Specifications
Gas Supply Requirements
- Australia
- New Zealand:
- United Kingdom:
Category: II
2H3P
(20, 37).
Flue Type: A
1.
* Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’
section for details).
Natural Gas (G20) Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Oven
Open Burner
(each)
Griddle
(each 300mm section)
Oven
Heat Input
(nett)
Nominal
6.5 kW 5.5 kW 6.5 kW 6.5 kW 5.5 kW 6.0 kW
Reduced
1.75 kW 1.85 kW 1.1 kW 1.75 kW 1.95 kW 1.05 kW
Gas Rate
(nett)
Nominal
0.69 m
3
/hr 0.58 m
3
/hr 0.69 m
3
/hr 0.51 kg/hr 0.43 kg/hr 0.47 kg/hr
Reduced
0.19 m
3
/hr 0.20 m
3
/hr 0.12 m
3
/hr 0.14 kg/hr 0.15 kg/hr 0.09 kg/hr
Supply Pressure
20 mbar 30 / 37 mbar
Burner Operating
Pressure (*)
9.5 mbar (*) 26 mbar (*)
Gas Connection
3
/
4
” B.S.P. Male
Pilot
200W 170W 170W 200W 150W 150W
Pilot
0.02 m
3
/hr 0.02 m
3
/hr 0.02 m
3
/hr 0.02 kg/hr 0.01 kg/hr 0.01 kg/hr
Natural Gas LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300 mm Griddle Section 21 MJ/hr 21 MJ/hr
- Oven 24 MJ/hr 24 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.95 kPa (*) 2.6 kPa (*)
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas LP Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300 mm Griddle Section 21 MJ/hr 21 MJ/hr
- Oven 24 MJ/hr 24 MJ/hr
Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.95 kPa (*) 2.6 kPa (*)
Gas Connection
3
/
4
” B.S.P. Male
Loading ...
Loading ...
Loading ...