Minimum or silent air purification speed.
Maximum or silent air purification speed.
Installation requirements
❏ This appliance must be connected to 220/240 V
50 Hz mains electricity supply using an earthed
plug.
❏ It must be protected with a 10 A slow-action fuse.
❏ Should an extension lead be needed, this lead
must be at least 1.5 mm
2
per terminal thick, no
more than 25 m. long and earthed.
❏ There is a cavity at the back of the appliance for
the mains electricity lead.
❏ Do not allow water to enter the appliance.
❏ Do not block the air inlets or outlets on your
appliance, especially when used for heating.
❏ To ensure correct appliance operation, maintain
minimum distances of 20 cm to adjacent objects.
see fig 4.
❏ The mains electricity supply connection cable
must only be replaced by authorised
members of the manufacturer’s Official
Technical Service.
❏ When the appliance is switched on and set to
work in dehumidification mode, the user may
hear a whistling or bubbling sound. There is
no cause for concern; these noises are not
symptomatic of a fault.
❏ Be careful on removing the tank from the
appliance when full of water. Hold the sides
gently but firmly and try to keep the tank in
as upright a position as possible at all times.
❏ Remember that when the appliance is turned
off, it is necessary to wait for approximately 3
minutes before turning it back on again. This
period of time is required in order to ensure
correct appliance operation.