Table of Parameters and Factory Settings
Parameter Function Set Range Default Parameter Function Set Range Default
Set Setpoint
-25°C
C3H Product
Temp. High
Temp. Alarm
C3L~40.0°C /
104°F
-15°C /
5°F
PAS Password 00~99 15 C3L Product
Temp. Low
Temp. Alarm
-40.0°C/-
40°F~C3H
-40°C /
-40°F
E1
Lowest set
-30°C / -22°F
C4
Hysteresis
0.1~20.0°C /
0.1°C /
point limit
Alarm
0.2~36.0°F
0.18°F
E2 Higher set
point limit
-10.0°C / 14°F
-10.0°C / 14°F C5 Start-up
Temp. Alarm
delay
00~99 min 60 min
E3 Temp.
Hysteresis
0.1~20.0°C /
0.2~36.0°F
3°C / 37.4°F C6 Temp. Alarm
Delay
00~99 min 3 min
E40 Turning On
delay time
00 ~10 min. 3 min. C7 Turn off
Relay
Alarm
00=do not alarm /
01= alarm
01
E41 Comp. start
delay time
00 ~10 min. 3 min. C8 The alarm
relay closed
after
silencing
alarm relay
switch
00=open /
01=close
00
E5 Offset on Air
Temperature
-10.0~10.0°C / -
18.0~18.0°F
2.0°C / 3.6°F
C9
Restart
time after
buzzer is
muted
00=do not start /
01 ~30 min=restart
time
10 min
E6 Offset on
Product
Temp.
-10.0~10.0°C / -
18.0~18.0°F
0.0°C / 32°F C10 Comp.
Force stop
time
01~99 min 99 min