UNIQUE UGP 2
6
6. Release the safety device control (A) and again check to see that the flame is
alight.
7. Adjust the thermostat knob (D) to desired temperature setting after 6 to 8
hours of operation.
8. To terminate gas operation, turn selector switch (E) to OFF position.
Electronic Ignition Module Location
The electronic ignition battery module is located
at the back of the appliance at the bottom left
side while facing the back of the appliance.
If the battery requires changing, turn knob to the
left to expose the battery, remove AAA battery
and replace with new one (positive facing
outwards), replace the knob and turn to the right
to close.
Shut Down Procedure – LP Gas
A. Turn selector knob “E” to “OFF” position.
B. Shut the gas off at the LP-gas supply cylinder when the appliance is not in use.
C. If the freezer will not be in operation for a period of weeks, it should be emptied,
defrosted, cleaned and the lid left open.
110V Operation
1. Make sure that the gas valve is turned off at the tank.
2. Ensure the electrical cord is plugged into a grounded outlet.
3. Turn the selector switch (E) to “AC” position. AC indicator light will illuminate.
4. Adjust the thermostat knob (D) to desired temperature setting after 6 to 8 hours