ENGLISH
MAIN SIGNAL XLR INPUT (BAL/UNBAL). The system accept female XLR input connectors
and line-level signals from a mixing console or other signal source.
SIGNAL LINK XLR OUTPUT. The output XLR male connector provides a loop trough for
speakers daisy chaining.
XOVER SIGNAL OUTPUT. The output XLR male connector provides a crossover high passed
signal (24 dB/octave) for satellites speakers.
INPUT SENSITIVITY. Controls the overall signal level at the input to the power amplifier. The
control ranges from + 10 dBu (maximum attenuation) to the –2 dBu sensitivity (maximum input
gain). The centre detent is +4 dBu (nominal level required to drive the amplifier at maximum
power).
XLOW CUT 30/45 Hz. This switch provides an high pass 24 dB/octave filtering at 30 or 45
Hz. This is really useful for indoor situations (no very low frequencies that can create resonant
sound) or when all the power shall be used in the 45 Hz - 100 Hz range.
XOVER 60/100 HZ. Provides 24 dB/octave low-pass filtering at 80 Hz if released, at 110 Hz
if pressed. The same crossover frequency in high-pass is available from XOVER OUTPUT XLR.
TIME DELAY ENCODER. This encoder provides a time delay setting expressed in meters.
TIME DELAY DISPLAY. Display the time delay setting.
POWER INDICATOR. Power on indicator. When the power cord is connected and the power
switch is turned on this indicator lights green.
STATUS INDICATOR. The status indicator blink orange if the main amplifier or power supply
REAR
PANEL
The TTS36-A amplifier section features:
- 2 x 2000 Watt digital amplifiers.
- PFC circuit.
- 7 x cooling speed controlled fans.
- Powercon AC input connector.