16 31-5000476 Rev. 0
ENGLISH
ELECTRICAL WIRING
Supply Wiring Drawing
• Indoor units and outdoor units should be connected to separate power breakers
Indoor units must share one single electrical breaker. Circuit breaker specifications should be calculated. It is
recommended to have both indoor & outdoor units connected to GFCI and surge devices.
WARNING
• Follow local codes when selecting wire gauge and connecting to building power.
• Use the cable strain relief clips and locking conduit clamps to prevent wires from being pulled off terminal posts.
• Unit must be properly grounded. Do not use water or gas piping, phone ground or lightning rod.
• Use only a properly sized circuit breaker. Use only properly sized copper conductors or electric shock could occur.
• Unit requires 208/230VAC - 2 conductor wires and a ground. No neutral.
All indoor units should be wired to the same breaker to prevent some of the units from being powered off while
others are energized.
• Controller wiring and refrigerant tubing can be arranged and ran together.
• Disconnect power from both outdoor and indoor units prior to servicing any component in the system.
L1(L) L2(N)
L1(L) L2(N)
L1(L) L2(N)
L1(L) L2(N)
......
Indoor 9Indoor 2Indoor 1
Ground Fault Interruptor
Circuit Breaker
Ground Fault Interruptor
Circuit Breaker
Outdoor
Power Source: 208/230V~, 60Hz
Power Source: 208/230V~, 60Hz