Base Grille Water Filtration System
Model TIWG2LfT2RFWG2 Capacity 200 Gallons (758 Liters)
Model TlWG2/T2RFWG2 Capacity 200 Gallons (758 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class II*; and against NSF/ANSl Standard 53 for the reduction of
Mercury, Benzene, Toxaphene, O-dichlorobenzene, and Carbofuran.
This system has been tested according to NSF/ANSl 42/53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSl 42/53.
Substance Reduction NSF Reduction Average Influent Challenge Maximum Average Minimum %Average %
Aesthetic Effects Requirements Influent Concentration Effluent Effluent Reduction Reduction
Chlorine Taste/Odor 50% reduction 2.0182 mg/L 2.0 mg/L _+10% 0.06 mg/L ** 0.0536 mg/L 97.03 97.34
Particulate Class II* 85% reduction 1333333 #/mL At east 10,000 part c es/mL 6600 #/mL 2325 #/mL 99.51 99.83
Contaminant NSF Reduction Average Influent Challenge Maximum Average Minimum %Average %
Reduction Requirements Influent Concentration Effluent Effluent Reduction Reduction
Lead: @ pH 6.5*** 0.010 mg/L 0.1533 mg/L 0.15 mg/L _+10% 0.0005 mg/L 0.0005 mg/L 99.67 99.67
Lead: @ pH 8.5*** 0.010 mg/L 0.1400 mg/L 0.15 mg/L _+10% 0.0007 mg/L 0.0006 mg/L 99.50 99.57
Mercury: @ pH 6.5 0.002 mg/L 0.0058 mg/L 0.006 mg/L _+10% 0.0002 mg/L 0.0002 mg/L 96.54 96.54
Mercury: @ pH 8.5 0.002 mg/L 0.0059 mg/L 0.006 mg/L _+10% 0.0005 mg/L 0.0003 mg/L 91.57 94.92
Benzene 0.005 mg/L 0.0154 mg/L 0.015 mg/L _+10% 0.0012 mg/L 0.0006 mg/L 92.22 96.34
O-Dichlorobenzene 0.6 mg/L 1.7571 mg/L 1.8 mg/L _+10% 0.0250 mg/L 0.0066 mg/L 98.58 99.63
Toxaphene 0.003 mg/L 0.015 mg/L 0.015 mg/L _+10% 0.001 mg/L 0.001 mg/L 93.33 93.33
Carbofuran 0.04 mg/L 0.0819 mg/L 0.08 mg/L _+10% 0.0400 mg/L 0.0213 mg/L 51.13 74.00
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter These contaminants are not necessarily in your water supply.
replacement requirements be carried out for the product to While testing was performed under standard laboratory
perform as advertised, conditions, actual performance may vary.
Use replacement filter T2RFWG2, part #4396841 In Canada,
use replacement filter T2RFWG2, part #4396841B.
2007 suggested retail price of $39.99 U.S.A./S49.99 Canada.
Prices are subject to change without notice.
Model TlWG2L: Style 1 - Press FILTER to check the status
of your water filter. If the filter indicator light is yellow, order a
new filter. If the filter indicator light is red, it is recommended
that you replace the filter.
Style 2 -When the filter indicator reads 10%, order a new
filter. When the filter indicator reads 0%, it is recommended
that you replace the filter.
Style 3- When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended that you
replace the filter.
Model TlWG2: Change the water filter every 6 months
depending upon your usage. If the water flow to the water
dispenser or ice maker decreases noticeably before 6 months
have passed, replace the water filter more often.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the "Assistance or Service" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate 0.5 gpm (1.9 Lpm) @ 60 psi
*Class II particle size: 1 um to <5 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
***Compliant for Lead reduction requirements under NSF/ANSl Standard 53 as tested by Pace Analytical Services, Inc.
(R_NSF is a registered trademark of NSF International.