29
TIP: Before proceeding, take note of the original burner bypass screw placement.
ADJUSTING THE OVEN BURNER FLAME
1) Light the burner and turn the thermostat to the 500ºF position,
2) Allow the oven to heat up for approximately 20 minutes then rotate the knob to
the 450ºF position
NOTE: The knob must be in the 450ºF position to access the by-pass screw
4) Remove the knob to gain to access to the thermostat by-pass.
5) Move the insulation to the side, away from the hole
6)Locatetheaccesspointforthethermostatby-passscrew-g1
7) Slowly screw the by-pass screw clockwise (approx 3/4 to one full rotation) until
youobtainaameofapproximately1/6”(0.16cm)inheight.
DO NOT OVERTIGHTEN.
8)Oncedesiredameheightisachieved
reattach the knob to the valve stem.
9) Following the conversion, set the oven
to300ºF,fullyopenthedoorandrmlyclosedoortoverifytheamedoesn’tex-
tinguish.Iftheameextinguishestheby-passscrewhasbeenoveradjustedand
needs to be slightly rotated counter clockwise, refer back to step 5 for re-adjust-
ment.
OVEN VALVE
Theovencontrolhasaamesafetydevicebuiltintothebodyofthethermostat.
Presenceofagasignitionsource(pilot)isveriedbyaamesafetyprobe.This
amesafetyprobeactuatestheinternalsafetydevicetoallowgasintotheoven
burner when the oven is turned on. If there is a loss of gas ignition during opera-
tion,theamesafetydevicewillcloseoffgasowtotheovenburnerandpilot.
Theovenburneroriceislocatedonabrassinjectorstudattherearoftheoven
undertheovenoor.Thisoriceisdedicatedtothegasforwhichtheovenistobe
used.Theoriceisnotadjustable.Itmustbechangedcompletelytoconvertfrom
one gas to the other. DO NOT DISCARD THE UNUSED ORIFICE. It should be
saved in order to convert the range back to its original fuel.
ADJUSTING THE TOP BURNER AND OVEN FLAME
(continued)
g1
Loading ...
Loading ...
Loading ...