Other Features
Indicator Lights
All indicator light descriptions apply when the Line Conditioner is plugged into a wall
outlet and turned on. (Available on select models only.)
A green “NORM” light will turn ON whenever your Line Conditioner is plugged in and
receiving nominal AC line voltage.
Yellow lights labeled “LOW” (or “BOOST”) and “HIGH” (or “TRIM”) will turn ON when
incoming voltage is above or below nominal AC line voltage.
Red lights labeled “VERY HIGH” or “VERY LOW” will turn ON when incoming voltage
is substantially above or below nominal AC line voltage.
A green “LINE OK” light will turn on when AC power is present and no wiring faults
are detected. When this light is illuminated, AC power is acceptable for connected
equipment.
A red “LINE FAULT” light will turn ON to indicate a wiring fault has been detected.
The condition should be investigated and repaired by a qualified technician as soon
as possible. A loose wall outlet may cause this light to come ON. Your Line
Conditioner will identify most common wiring faults (but not necessarily every
possible type of fault).
Basic Operation
IEC-320-C13
(220/240V)
NEMA 5-15R*
(220/240V)
NEMA 6-15R*
(220/240V)
* Available on select models.
AC Receptacles
The receptacles provide your connected equipment with AC line power
during normal operation. They adjust incoming voltage to provide equipment
with nominal 220/240V power. The receptacles also protect your equipment
against damaging surges and line noise, eliminating the need for external
surge suppression.
Note: As the Line Conditioner corrects fluctuating input voltages, the unit
will make a gentle clicking sound. The frequency of the clicking will depend
on the quality of the utility power in your particular area. The clicking is
normal and indicates the Line Conditioner is compensating for fluctuating
input voltages as described in this manual.
Circuit Breaker (Available on select models)
If the rated capacity of the Line Conditioner is exceeded at any time, the
circuit breaker will open (trip). Remove the overload and let the circuit
breaker cool for one minute. Reset the circuit breaker by pushing in the
plunger.