When transporting your generator:
Empty the gas tank (see “Emptying the Gas Tank” in the “Maintenance” section).
Disconnect the spark plug.
Do not obstruct any ventilation openings & keep the generator in a cool dry area.
CAUTION: Never place any type of storage cover on the generator while it is still
hot.
MAINTENANCE AND CARE (CONTINUED)
52
Storage and Transportation
Storage Period Storage Preparation
If you plan on starting
the same day
1. Turn o the main breaker.
2. Allow the unit to run 3 - 5 minutes.
3. Turn o the engine switch.
4. Store.
If you plan on starting
the unit again within
30 days
1. Turn o the main breaker.
2. Allow the unit to run 3 - 5 minutes.
3. Turn o the fuel valve.
4. Allow the unit to stall out.
5. Turn o the engine switch.
6. Add fuel stabilizer to the gas remaining in the tank.
7. Store.
If you do not plan to
start the unit for
longer than 30 days
1. Turn o the main breaker.
2. Allow the unit to run 3 - 5 minutes.
3. Turn o the fuel valve.
4. Allow the unit to stall out.
5. Turn o the engine switch.
6. Drain the fuel tank (See “Emptying the Gas Tank” in the “Maintenance” section)
7. Drain the carburetor
a. Remove the drain bolt from the carburetor.
b. Drain the small amount of remaining fuel from the carburetor bowl.
8. Oil the cylinder
a. Remove the spark plug.
b. Put 2 tbsp. of 10w30 motor oil directly into the spark plug hole
c. Pull the recoil start one time.
d. Replace the plug.
9. Remove the battery and place it on tender indoors.
Loading ...