Whirlpool RCS3014RS03 electric counter unit

User Manual - Page 7

For RCS3014RS03.

PDF File Manual, 16 pages, Download pdf file

Loading ...
Loading ...
Loading ...
For all models except 15" (38.1 cm) model: Electrical Connection Options
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
For 15" (38.1 cm) model only:
Electrical Shock Hazard
Disconnect power before servicing.
Use 12 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
For cooktops with a 4-wire cable:
If your home has: And you will be Go to Section:
connecting to:
4-wire direct A fused 4-Wire Cable from
disconnect or Power Supply to
circuit breaker 4-Wire Cable from
box Cooktop
(12_7 cm)
3-wire direct A fused 3-Wire Cable from
disconnect or Power Supply to
circuit breaker 4-Wire Cable from
box Cooktop
For cooktops with a 3-wire cable:
If your home has: And you will be Go to Section:
connecting to:
4-wire direct A fused 4-Wire Cable from
disconnect or Power Supply to
circuit breaker 3-Wire Cable from
box Cooktop
(12_7 cm)
3-wire direct A fused 3-Wire Cable from
disconnect or Power Supply to
circuit breaker 3-Wire Cable from
box Cooktop
This cooktop is manufactured with a frame connected, green or
bare ground wire. Connect the cooktop cable to the junction box
through the UL listed or CSA approved conduit connector.
Loading ...
Loading ...
Loading ...