3 phases (220240 V~, 50-60 Hz)
To reach the rated maximum power a fuses of 32A is needed.
Install a jumper between terminals 4 and 5.
For appliance types: BI9CA, BI9CB, BI9CC .
NOTE!
Note: The appliance type can be found on the rating plate on the bottom of the appliance.
Voltage between lines must be 220240 V~. Power cord core cross sectional area should be at least
as listed in Table for the following current limiter settings which should be adjusted to your circuit
breakers:
Number and cross section
of Power cord wires
Power cord
type
Connection typeCurrent limiter
settings
4x4,0 mm²H05V2V2-F3 phase conductors3x16A
4x4,0 mm²H05V2V2-F3 phase conductors3x13A
4x4,0 mm²H05V2V2-F3 phase conductors3x10A
4x4,0 mm²H05V2V2-F3 phase conductors3x06A
3x1,5 mm²H05V2V2-F3 phase conductors2x16A
3x1,5 mm²H05V2V2-F3 phase conductors2x13A
3x1,5 mm²H05V2V2-F3 phase conductors2x10A
3x1,5 mm²H05V2V2-F3 phase conductors2x06A
3x6,0 mm²H05V2V2-F2 phase conductors1x48A
3x6,0 mm²H05V2V2-F2 phase conductors1x35A
3x4,0 mm²H05V2V2-F2 phase conductors1x32A
3x4,0 mm²H05V2V2-F2 phase conductors1x25A
3x4,0 mm²H05V2V2-F2 phase conductors1x20A
3x4,0 mm²H05V2V2-F2 phase conductors1x16A
The following connections are possible.
58
Electrical installation