PRODUCT DATA SHEETS
Base Grille Water Filtration System
Tested and certified by NSF International against ANSI/NSF
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class I1"; and against ANSI/NSF Standard 53 for the reduction of Lead,
Mercury, Benzene, Toxaphene, p-dichlorobenzene, and Carbofuran.
This system has been tested according to ANSl/NSF 42/53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in ANSl/NSF 42/53.
Model WF-NL240V/NL240V Capacity 240 Gallons (908 Liters)
Substance Reduction NSF Reduction Average Influent Challenge Maximum Average Minimum %Average %
Aesthetic Effects Requirements Influent Concentration Effluent Effluent Reduction Reduction
Chlorine Taste/Odor _>50% 1.94 mg/L 2.0 mg/L _+10% 0.05 mg/L 0.05 mg/L 97.4% 97.4%
Particulate Class II* At least 10,000 100,000/mL** 88.0%
40,667/mL 95.1%_>85% 833,333/mL particles/ml
Contaminant NSF Reduction Average Influent Challenge Maximum Average Minimum %Average %
Reduction Requirements Influent Concentration Effluent Effluent Reduction Reduction
Lead: (-®pH 6.5 0.01 mg/L 0.15 mg/L*** 0.15 mg/L _+10% 0.001 mg/L 0.001 mg/L 99.3% 99.3%
Lead: @ pH 8.5 0.01 mg/L 0.148 mg/L*** 0.15 mg/L _+10% 0.003 mg/L 0.001 mg/L 97.9% 99.0%
Mercury: @ pH 6.5 0.002 mg/L 0.006 mg/L 0.006 mg/L _+10% 0.0002 mg/L 0.0002 mg/L 96.60% 96.6%
Mercury: @ pH 8.5 0.002 mg/L 0.0061 mg/L 0.006 mg/L _+10% 0.0009 mg/L 0.00052 mg/L 85.2% 91.8%
Benzene 0.005 mg/L 0.014 mg/L 0.015 _+10% 0.0005 mg/L 0.0005 mg/L 96.06% 96.06%
p-dichlorobenzene 0.075 mg/L 0.235 mg/L 0.225 _+10% 0.0019 mg/L 0.0009 mg/L 99.1% 99.6%
Toxaphene 0.003 mg/L 0.014 mg/L 0.015 _+10% 0.0012 mg/L 0.001 mg/L 92.7% 92.6%
Carbofuran 0.04 mg/L 0.077 mg/L 0.080 _+10% 0.031 mg/L 0.0064 mg/L 61.03% 91.94%
Model WF-L400V/L400V Capacity 400 Gallons (1514 Liters)
Substance Reduction NSF Reduction Average Influent Challenge Maximum Average Minimum %Average %
Aesthetic Effects Requirement Influent Concentration Effluent Effluent Reduction Reduction
Chlorine Taste/Odor _50% 1.94 mg/L 2.0 mg/L _+10% 0.05 mg/L 0.05 mg/L 97.4% 97.4%
Particulate Class I1" _85% 833,333/mL Atparticles/mlleast10,000 100,000/mL** 40,667/mL 88.0% 95.1%
Contaminant NSF Reduction Average Influent Challenge Maximum Average Minimum %Average %
Reduction Requirement Influent Concentration Effluent Effluent Reduction Reduction
Lead: @ pH 6.5 0.01 mg/L 0.15 mg/L*** 0.15 mg/L _+10% 0.001 mg/L 0.001 mg/L 99.3% 99.3%
Lead: @ pH 8.5 0.01 mg/L 0.148 mg/L*** 0.15 mg/L _+10% 0.003 mg/L 0.0014 mg/L 97.9% 99.3%
Mercury: @ pH 6.5 0.002 mg/L 0.0061 mg/L 0.006 mg/L _+10% 0.0002 mg/L 0.0002 mg/L 96.60% 96.6%
Mercury: @ pH 8.5 0.002 mg/L 0.0061 mg/L 0.006 mg/L _+10% 0.0009 mg/L 0.00052 mg/L 85.2% 91.8%
Benzene 0.005 mg/L 0.014 mg/L 0.015 _+10% 0.0005 mg/L 0.0005 mg/L 96.06% 96.06%
p-dichlorobenzene 0.075 mg/L 0.235 mg/L 0.225 _+10% 0.0019 mg/L 0.0009 mg/L 99.1% 99.6%
Toxaphene 0.003 mg/L 0.014 mg/L 0.015 _+10% 0.0012 mg/L 0.001 mg/L 92.7% 92.6%
Carbofuran 0.04 mg/L 0.077 mg/L 0.080 _+10% 0.031 mg/L 0.0064 mg/L 61.03% 91.94%
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-NL24OV: Change cartridge at least every 6 months.
Use replacement cartridge NL240V, part #4396509. 2006
suggested retail price of $35.99 U.S.A./S59.95 Canada. Prices
are subject to change without notice.
Model WF-L400V: The filter monitor system measures the
amount of water that passes through the filter and alerts you to
replace the filter. When 90% of the filter's rated life is used, the
filter indicator light changes from green to yellow. When 100% of
the filter's rated life is used, the filter indicator light changes from
yellow to red, and it is recommended that you replace the filter.
Use replacement cartridge L400V, part #4396509. 2006
suggested retail price of $35.99 U.S.A./S59.95 Canada. Prices
are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
Refer to the front cover or "Assistance or Service" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate 0.5 gpm (1.9 L/min.) @ 60 psi.
*Class II particle size: >1 to <5
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
***These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
NSF is a registered trademark of NSF International.