4
9. Install grille.
Install 100W max. incandescent light bulb. Plug in light. Squeeze grille
springs and insert into slots in housing. Push grille up against ceiling.
7. Connect 4-in. round duct.
Pull existing ducting through housing discharge opening and tape ducting
to duct connector. Push connector/ducting back through opening. Engage
tabs and secure with screw from parts bag.
1
2
3
TABS
*
8. Install blower.
Re-install blower removed in Step1. Secure blower with 2 screws from
parts bag and plug blower into black receptacle.
5. Connect wiring.
Bend tab to expose desired access
hole. Connect power cable to
housing with appropriate UL
approved connector. Connect black
to black, white to white, black to
red and green to green or bare wire.
Re-install wiring panel and secure
with screw from parts bag.
WIRING DIAGRAM
99045965B
SWITCH BOX
LIGHT
FAN
DUAL CONTROL
(purchase separately)
WHITE
BLACK
RED
GROUND
(bare)
WIRING PLATE
120 VAC LINE IN
RECEPTACLE
(FAN)
RECEPTACLE
(LIGHT)
6. Connect wiring.
Bend tab to expose desired access
hole. Connect power cable to
housing with appropriate UL
approved connector. Connect black
to black, white to white, black to
red and green to green or bare
wire. Re-install wiring panel and
secure with screw from parts bag.
Depending upon model - your
grille may look different.
If grille spring becomes
dislodged from grille -
snap it back into place
as shown.
7. Finish ceiling - then skip to Step 8.
6. Mount fan to ceiling structure.
Mount housing to
ceiling structure with
standard drywall
or wood screws in
locations shown.
(Some models include
mounting screws.)
*Center hole optional.
2
10½-in.
9¾-in.
JOIST
3. Remove old fan and prepare ceiling.
Existing fan housings are typically attached to the structure:
with screws, nails, or staples, which must be removed.
with hangers or rails which are fastened to joists and must be
removed along with housing.
A pry bar may be needed to remove the old housing.
1
4. Fold mounting
ears at against
housing.
RETROFIT INSTALLATION
Enlarge ceiling opening
(if necessary) to 9¾”
parallel to joist) by 10½”
(perpendicular to joist).
(Some models have a
cut-out template on side
of carton.) Leave ductwork
and wiring in place.