Ultrasonic Disk
Clean the disk with the brush only.
No other cleaning tool should be used.
BRUSH ONLY.
E-6
E-7
CLEANING (cont.)
ULTRASONIC DISK
1. Unplug unit. Remove the tank and empty all water from unit base and tank.
2. Locate the ultrasonic disk on the inside of the base unit.
3. Use ONLY the enclosed cleaning brush to gently
clean disk and remove build up and deposits.
Do not scrub or scrape the ultrasonic disk.
If scale becomes difficult to remove with brush:
1. Fill the tank with: mixture of 1 tsp. white vinegar and 1 tsp. water.
2. Let solution stand for 5 minutes.
3. With the vinegar in the tank, clean all interior surfaces with a soft cloth or brush to help remove scale.
4. Also check mist nozzle and under float in water tank. Clean as needed.
5. Rinse the tank thoroughly with water to remove scale and vinegar solution.
END OF SEASON STORAGE
Follow the Cleaning and Descaling instructions when the humidifier will be stored at the end of the season.
Dry the humidifier completely before storing. DO NOT store with water inside the Base or Water Tank.
Pack the unit in its original carton and store in a cool, dry location.
NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING
YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER
OR PERSONAL INJURY.
TROUBLE SHOOTING GUIDE
Water vapor and humidity
are not produced.
Power Plug: Unplug and then try again.
Power Failure: When the power is returned, try again.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
PROBLEM
SOLUTION
Air blows but water vapor
is not produced.
Excessive Water: Remove a certain amount of water from the tank.
Detergent residue and/or oil ingredients from cosmetics, may be in
tank; wash out tank and try again.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
If you use hard water, replace with softer water.
Humidity level is low.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
The water in the unit is too cold: Replace with cool, but not cold water.
Damage on the ultrasonic disk: Contact Customer Service
The humidity has
a bad smell.
Poor maintenance or dirty water: Clean the product thoroughly,
and fill it with fresh water.
White dust is forming on
nearby furniture.
Hard water may deposit a certain amount of dust. Dust in the air also
settles because of added humidity in the room. Use distilled water if
this becomes a nuisance.
Unit has stopped working.
No or low water. Unplug unit and refill tank.
Water is accumulating
outside of unit or area
surrounding unit.
Saturation of humidity. Lower mist control setting.
Unit not level and water is accumulating. Unplug and place on level
surface. Raise unit on a water-resistant level surface 2-3 feet off of floor.
Increased noise level.
Unit must be placed on a flat, level, hard surface.
Make sure it is NOT placed on a soft or absorbent surface.
Red light above power button.
Indicates low water. Unplug and refill tank.
Looking down
at the inside of
empty tank.
DESCALING
• Depending on usage and water type, cleaning to remove scale may be required
weekly or every other week to optimize unit performance.
• If you live in a hard water area, we recommend the use of distilled water for your
humidifier. This will help reduce the precipitation of minerals or ‘white dust’.
• Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.
Cannot smell aroma scent.
Add a few more drops of oil to the aroma
pad or replace aroma pad with a new one.
Float
Loading ...
Loading ...
Loading ...