32
Refer to Program 5 for modifying this setting.
94 Selection of Battery Type Custom
The factory default frequency for inverters is 60Hz. Normally, manufacturers build electrical
devices for a certain amount of Current, Voltage and Hertz (Cycles) which is mentioned on the
name plate. The Current is dependent of the Voltage and the Hertz supplied to an electric motor
or appliance. This program allows you to set the frequency range of the AC input source.
Special cases might require a wider frequency range than normal Utility and Generator outputs.
93 Input Frequency Range
Item 92 takes effect only when the user selects "UPS" in item 03. 03 project has two options, is
to select the width of the input voltage range, mainly the input voltage lower limit is different. In
UPS mode, when the input range is narrow, the user can set the lower voltage limit by himself.
1V is the first gear.
In the AC230V output inverter will have 92 items, AC120V output inverter does not have this
function
92 AC Input Voltage Range
93
This setting will not be modifiable if users choose a pre-set battery voltage.
NOTE
Special 40-70HZ
General 50HZ 45-55HZ
/ 60HZ 55-65HZ
Frequency Range
94
29
The default setting is 10.0V. Setting range is from 10.0V
to 12.0V with increments of 0.1V. This setting must be at
least 0.5V lower than setting #98 Low Battery Alarm.
V
BATT
Lithium battery
If selected, battery charge voltage
and battery low open charging
can be set up in program 26,27
Other battery
If selected ,battery charge voltage
can be set up in program 26,27
Selection of battery type
AC230V output inverter to have this function