ADDiTiONAL THINGS YOU SHOULD KNOW
Now that you understand the basic operation functions, here are more control features with which you should became
familiar.
The "cool" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents
overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time.
There is a 2-Second delay for the compressar shutting dawn when selecting FAN ONLY/HEAT. This is to cover the
possibility of having to roll through to select another mode.
The control will maintain the set temperature within 2 degrees Fahrenheit, between 60°F and 90°F (in cool mode),
55°F and 80°F (in heat mode).
The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the
other and back, press and hold bath the "TEMP/TIMER" Up(A) and Dawn (v) buttons for 3 seconds.
FAULTCODES :
If the display reads "HS", "ES" or "AS", a sensor has failed. Contact 1-800-4-MY-HOME® for repair.
Heat sensor Evaporator coil sensor Air temperature sensor
AUTO RE-START :
After a power outage, the unit will remember the last setting and return the unit to the same setting once power is restored.
FRESH AiR VENT CONTROL ( On 253.79184 model )
1. Pushed In (Fig. 1) - Recirculates inside air
2. Partially Pulled Out (Fig. 2) - Draws fresh air into room
3. Fully Pulled Out (Fig. 3) - Exhausts air from room and draws fresh
air into room
Figure 1 (VENT CLOSED )
Figure 2 ( VENT OPEN ) Figure 3 ( VENT & EXHAUST OPEN )