Installation
35
EN
5 Installation
5.1 Minimum clearance to
combustible surfaces
Freestanding cooker
A 600 mm (Overhead) measured from the
highest part of the highest burner and 750
mm for an exhaust fan.
B 200 mm (Vertical combustible surface)
measured form the edge of the nearest
burner.
C 10 mm (Horizontal combustible surface)
below the hob.
5.2 Gas connection
Carefully screw the connector 3 to the
appliance’s gas connector 1 (1/2” thread
ISO 228-1), placing the supplied seal 2
between them. This appliance must be
installed by an authorised person in
accordance with this instruction manual,
AS/NZS 5601.1 – Gas installations
(installation and pipe sizing), local gas
fitting regulations, local electrical
regulations, local health regulations,
Building Code of Australia and any other
government authority.
Refer to AS/NZS 5601
(Protection of a combustible
surface) if the above minimum
clearances cannot be achieved.
The appliance connection point
shall be accessible with the
appliance installed.
Maximum height of the top pan
support with respect to the surface
that supports the appliance is
912mm.
Gas leak
Danger of explosion
• After carrying out any operation, check
that the tightening torque of gas
connections is between 10 Nm and 15
Nm.
If required, use a pressure regulator that
complies with current regulations.
• At the end of the installation, check for
any leaks with a soapy solution, never
with a flame.