E-16
SPECIFICATIONS
*1 • The recommended room size is an area in which a given amount of dust particles can be removed in
30 minutes.
*2 • Room size in which approximately 25000 ions per cubic centimeter can be measured in the centre of
the room when the unit is placed next to a wall, is running at maximum settings, and is at a height of
approximately 1.2 meters from the À oor.
Standby Power
When the unit’s power plug is inserted in a wall outlet it consumes about 1.0 watts of standby power in
order to operate electrical circuits.To conserve energy, unplug the power cord when the unit is not in use.
Power supply
220 V 50 Hz
Fan Speed Adjustment
FULL POWER MAX MED LOW
CLEAN AIR
Fan Speed (m
3
/hour)
330
180 115 60
Rated Power (W)
78
24 13 6.5
Noise Level (dBA)
53
42 34 24
Recommended Room Size (m
2
)*1
~40
High density Plasmacluster ion recommended room size (m
2
)*2
~25
Cord Length (m)
2.0
Dimensions (mm)
650 (W) × 178 (D) × 440 (H)
Weight (kg)
9.1
FACTORY
USE ONLY
Printed in China
TINS-A870KKRZ 15K-
CN 1